22 results (0,17626 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Nuaire Xboxer XBC-10 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-10 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-10 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal) Standard model is available, additional units with extras are available include the electric preheater model and the Low-Pressure Hot Water (LPHW) heater model. Supplied with terminal box for supply and extract fan motor wiring and for interfacing to custom built control panels Nuaire XBC range of high efficiency heat recovery ventilation units designed for ceiling void applications and are suitable for external use with weather roof. Designed to save energy, improve indoor air quality, and provide the lowest noise breakout when used with Nuaire matched attenuators. Please note that all XBC units are supplied as eft hand units as standard, unless other wise stated on your order. Key Features: High heat exchange efficiency - Up to 95% Low noise Units are aluzinc, asymmetric, high mass, double skinned wall construction with specialist acoustic treatment Compact & flexible - lowest case height (by duty) with unique supply/extract are on unit centreline, intake/extract connections are configurable on site to either side of the unit. Optimum performance – Backward curved impellers and IP54 EC motors provide low specific fan powers and step-less speed control without tonal noise generation. Blowers are ErP 2015 compliant. The unit is designed for side access as standard and must be installed with a minimum of 260mm clearance from a wall or barrier. This will provide access to filters, coil, fan, heat exchanger condensate tray and pump. Technical Features Up to 75% efficient Voltage / Phase / Frequency – 230V / 1 phase / 50 Hz Input Power (W) - 160 Max operating temperature – 55°C Maximum fan speed (RPM) - 3200 Unit Weight (kg) – 195 Sound level @3m dB(A) – 24 – 46 G4 extract and supply filters Counter plate heat exchanger 100% bypass DimensionsL x W x D – 1600mm x 1000mm x 260mm Benefits of working with BPC Ventilation

GBP 7636.20
1

Nuaire Xboxer XBC-15 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-15 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-15 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal) Standard model is available, additional units with extras are available include the electric preheater model and the Low-Pressure Hot Water (LPHW) heater model. Supplied with terminal box for supply and extract fan motor wiring and for interfacing to custom built control panels Nuaire XBC range of high efficiency heat recovery ventilation units designed for ceiling void applications and are suitable for external use with weather roof. Designed to save energy, improve indoor air quality, and provide the lowest noise breakout when used with Nuaire matched attenuators. Please note that all XBC units are supplied as eft hand units as standard, unless other wise stated on your order. Key Features: High heat exchange efficiency - Up to 95% Low noise Units are aluzinc, asymmetric, high mass, double skinned wall construction with specialist acoustic treatment Compact & flexible - lowest case height (by duty) with unique supply/extract are on unit centreline, intake/extract connections are configurable on site to either side of the unit. Optimum performance – Backward curved impellers and IP54 EC motors provide low specific fan powers and step-less speed control without tonal noise generation. Blowers are ErP 2015 compliant. The unit is designed for side access as standard and must be installed with a minimum of 260mm clearance from a wall or barrier. This will provide access to filters, coil, fan, heat exchanger condensate tray and pump. Technical Features Up to 75% efficient Voltage / Phase / Frequency – 230V / 1 phase / 50 Hz Input Power (W) - 160 Max operating temperature – 60°C Maximum fan speed (RPM) - 4000 Unit Weight (kg) – 195 Sound level @3m dB(A) – 26 – 51 G4 extract and supply filters Counter plate heat exchanger 100% bypass DimensionsL x W x D – 1600mm x 1000mm x 260mm Benefits of working with BPC Ventilation Number 1 leading MVHR and ventilation system specialists Large range of

GBP 8026.10
1

Komfovent Domekt R-700-V Heat Recovery Unit

Komfovent RHP 1200 - RHP 1200 9.3/7.9 UV C5

Komfovent RHP 1200 - RHP 1200 9.3/7.9 UV C5

Komfovent RHP 1200-UV Air Handling Unit - RHP 1200 9.3/7.9 UV C5 Key Features Extremely high energy efficiency Provides total comfort all year long Supplies fresh, clean and dust free air Heating and humidity recovery in winter Cooling and dehumidifying in summer Plug and play installation Compact design Provides Ventilation, Cooling, supplementary heating, air filtration and humidity control *Additional accessories may be required Technical Features Suitable for home sizes up to 500m2 Maximum airflow rate - 1300m3/h Weight - 260kg Sound level @ 3m - 45dB(A) Dimensions W x H x D - 1505mm x 905mm x 905mm Duct diameter - 250mm Two Step Heating and Cooling RecoveryTo reach maximum efficiency these units are designs to recovery energy in two steps Step 1: Recovery by enthalpy rotary heat exchanger Step 2: Recovery by reversible heat pump Cooling Mode - due to cooling recovery by rotary heat exchanger, the air temperature after the rotor is lower than the outside air temperature. Condensation temperature in this case is lower, which results in reduced compressor electricity consumption compared with outdoor condensing unit Heating Mode - a highly efficient rotary heat exchanger is used for first-stage heat recovery, recovering the biggest part of the heat of extracted air. For second-stage heat recovery and supply air temperature control a heat pump is used Controllability Intelligent control with algorithms and reliable components to ensure safe and efficient operation. This unit can be controlled via a digital C5.1 controller ConstructionRHP units are constructed of galvanized steel sheets, which are powder coated. Mineral wool is used for thermal insulation and sound attenuation. Unit cover panels are 45 mm thick.

GBP 16643.00
1

Komfovent RHP 800-U Air Handling Unit

Komfovent RHP 800-U Air Handling Unit

Komfovent RHP 800-U Air Handling Unit - RHP-800 C6/5.8-UV/UH Key Features Extremely high energy efficiency Provides total comfort all year long Supplies fresh, clean and dust free air Heating and humidity recovery in winter Cooling and dehumidifying in summer Plug and play installation Compact design Provides Ventilation, Cooling, supplementary heating, air filtration and humidity control *Additional accessories may be required Technical Features Suitable for home sizes up to 500m2 Maximum airflow rate - 800m3/h Weight - 255kg Sound level @ 3m - 40dB(A) Dimensions W x H x D - 1505mm x 905mm x 905mm Duct diameter - 250mm Two Step Heating and Cooling RecoveryTo reach maximum efficiency these units are designs to recovery energy in two steps Step 1: Recovery by enthalpy rotary heat exchanger Step 2: Recovery by reversible heat pump Cooling Mode - due to cooling recovery by rotary heat exchanger, the air temperature after the rotor is lower than the outside air temperature. Condensation temperature in this case is lower, which results in reduced compressor electricity consumption compared with outdoor condensing unit Heating Mode - a highly efficient rotary heat exchanger is used for first-stage heat recovery, recovering the biggest part of the heat of extracted air. For second-stage heat recovery and supply air temperature control a heat pump is used Controllability Intelligent control with algorithms and reliable components to ensure safe and efficient operation. This unit can be controlled via a digital C5.1 controller ConstructionRHP units are constructed of galvanized steel sheets, which are powder coated. Mineral wool is used for thermal insulation and sound attenuation. Unit cover panels are 45 mm thick.

GBP 14348.71
1

Komfovent RHP 400-V Air Handling Unit

Komfovent RHP 400-V Air Handling Unit

Komfovent RHP 400-V Air Handling Unit Product Part Number Komfovent RHP-400V Rotary wheel vertical unit with heat pump - RHP-400V Description Komfovent RHP range are air handling units with an integrated heat pump, this unit features all HVAC systems in one unit providing complete indoor microclimate control. Komfovent RHP 400-V air handling unit provides ventilation in premises up to 220m2. Technical Features Suitable for home sizes up to 220m2 Maximum airflow rate - 398m3/h Weight - 106kg Sound level @ 3m - 44dB(A) Dimensions W x H x D - 712mm x 892mm x 618mm Duct diameter 160mm Two Step Heating and Cooling Recovery To reach maximum efficiency these units are designs to recovery energy in two steps Step 1: Recovery by enthalpy rotary heat exchanger Step 2: Recovery by reversible heat pump Cooling Mode Due to cooling recovery by rotary heat exchanger, the air temperature after the rotor is lower than the outside air temperature. Condensation temperature in this case is lower, which results in reduced compressor electricity consumption compared with outdoor condensing unit Heating Mode  A highly efficient rotary heat exchanger is used for first-stage heat recovery, recovering the biggest part of the heat of extracted air. For second-stage heat recovery and supply air temperature control a heat pump is used Controllability Intelligent control with algorithms and reliable components to ensure safe and efficient operation. This unit can be controlled via a digital C5.1 controller Construction RHP units are constructed of galvanized steel sheets, which are powder coated. Mineral wool is used for thermal insulation and sound attenuation. Unit cover panels are 45 mm thick.

GBP 7251.69
1

BSK Plus 25 Commercial Heat Recovery Unit

BSK Plus 25 Commercial Heat Recovery Unit

BSK Plus 25 Commercial Heat Recovery Unit Product Part Number BSK 2500 m3h/r Horizontal MVHR - digital control - 350mm - BRHR Plus 25 BSK 2500 m3h/r Horizontal MVHR - digital control - 350mm - 10kw pre heater - BRHR Plus 25+pre heater BSK 2500 m3h/r Horizontal MVHR - digital control - 350mm - 16kw post heater - BRHR Plus 25+post heater BSK 2500 m3h/r Horizontal MVHR - digital control - 350mm - 16kw water heater - BRHR Plus 25+water heater Key Features Thin, flat profile is perfect for ceiling mounting. Self-motorized EC fans Aluminum plated, counter-flow heat exchangers with up to 90% high thermal efficiency. Provides up to 85% heat recovery Plug and play electrical connections 100% Summer bypass Highly efficient aluminium heat exchanger Thin, flat profile is perfect for ceiling mounting EC fans with lower power consumptions 2 x G4 filters with side panel allowing easy access for maintenance Technical Features Airflow capacity - 2000 m3h/r @ 100Pa BSK Plus Commercial Heat Recovery units are available with a preheater, post heater or a water heater H x W x L: 540mm x 1650mm x 1700mm 400mm duct connections Optional Accessories Water Heater Pre-Heater Post Heater Control Options Free cooling Boost mode De-frost mode Automated weekly schedules Temperature or humidity trigged automation Boost Mode Boost mode makes the BSK Heat Recovery Unit to run at full capacity in order to quickly ventilate the surroundings. This mode can be triggered in various ways. Built-in humidity sensor can detect the humidity level of the returning air and automatically initiate Boost Mode when a set level of humidity is reached to quickly dissipate the moisture to prevent it building up. Alternatively, if an external aspirator is connectedto the “boost port” of the device, when the aspirator is turned on, the device also enters Boost Mode to help with the

GBP 6750.80
1

Nuaire Xboxer XBC-55 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-55 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-55 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal) Standard model is available, additional units with extras are available include the electric preheater model and the Low-Pressure Hot Water (LPHW) heater model. Supplied with terminal box for supply and extract fan motor wiring and for interfacing to custom built control panels Nuaire XBC range of high efficiency heat recovery ventilation units designed for ceiling void applications and are suitable for external use with weather roof. Designed to save energy, improve indoor air quality, and provide the lowest noise breakout when used with Nuaire matched attenuators. Please note that all XBC units are supplied as eft hand units as standard, unless other wise stated on your order. Key Features: High heat exchange efficiency - Up to 95% Low noise Units are aluzinc, asymmetric, high mass, double skinned wall construction with specialist acoustic treatment Compact & flexible - lowest case height (by duty) with unique supply/extract are on unit centreline, intake/extract connections are configurable on site to either side of the unit. Optimum performance – Backward curved impellers and IP54 EC motors provide low specific fan powers and step-less speed control without tonal noise generation. Blowers are ErP 2015 compliant. The unit is designed for side access as standard and must be installed with a minimum of 260mm clearance from a wall or barrier. This will provide access to filters, coil, fan, heat exchanger condensate tray and pump. Technical Features Up to 75% efficient Voltage / Phase / Frequency – 230V / 1 phase / 50 Hz Max operating temperature – 45°C Maximum fan speed (RPM) - 2400 Unit Weight (kg) – 375 Sound level @3m dB(A): 35 – 58 G4 extract and supply filters Counter plate heat exchanger 100% bypass Dimensions (standard model)L x W x D – 1900mm x 1560mm x 407mm

GBP 17728.51
1

BSK Plus 30 Commercial Heat Recovery Unit

BSK Plus 30 Commercial Heat Recovery Unit

BSK Plus 30 Commercial Heat Recovery Unit Product Part Number BSK 3000 m3h/r Horizontal MVHR - digital control - 350mm - BRHR Plus 30 BSK 3000 m3h/r Horizontal MVHR - digital control - 350mm - 10kw pre heater - BRHR Plus 30+pre heater BSK 3000 m3h/r Horizontal MVHR - digital control - 350mm - 23kw post heater - BRHR Plus 30+post heater BSK 3000 m3h/r Horizontal MVHR - digital control - 350mm - 23kw water heater - BRHR Plus 30+water heater Key Features Thin, flat profile is perfect for ceiling mounting. Self-motorized EC fans Aluminum plated, counter-flow heat exchangers with up to 90% high thermal efficiency. Provides up to 85% heat recovery Plug and play electrical connections 100% Summer bypass Highly efficient aluminium heat exchanger Thin, flat profile is perfect for ceiling mounting EC fans with lower power consumptions 2 x G4 filters with side panel allowing easy access for maintenance Technical Features Airflow capacity - 3000 m3h/r @ 100Pa BSK Plus Commercial Heat Recovery units are available with a preheater, post heater or a water heater H x W x L: 675mm x 1650mm x 1850mm 450mm duct connections Optional Accessories Water Heater Pre-Heater Post Heater Control Options Free cooling Boost mode De-frost mode Automated weekly schedules Temperature or humidity trigged automation Boost Mode Boost mode makes the BSK Heat Recovery Unit to run at full capacity in order to quickly ventilate the surroundings. This mode can be triggered in various ways. Built-in humidity sensor can detect the humidity level of the returning air and automatically initiate Boost Mode when a set level of humidity is reached to quickly dissipate the moisture to prevent it building up. Alternatively, if an external aspirator is connectedto the “boost port” of the device, when the aspirator is turned on, the device also enters Boost Mode to help with the

GBP 7069.67
1

BSK Plus 15 Commercial Heat Recovery Unit

BSK Plus 15 Commercial Heat Recovery Unit

BSK Plus 15 Commercial Heat Recovery Unit Product Part Number BSK 1500m3h/r Horizontal MVHR - digital control - 250mm - BRHR Plus 15 BSK 1500m3h/r Horizontal MVHR - digital control - 250mm - 6kw pre heater - BRHR Plus 15+pre-heater BSK 1500m3h/r Horizontal MVHR - digital control - 250mm - 11kw post heater - BRHR Plus 15+post heater BSK 1500m3h/r Horizontal MVHR - digital control - 250mm - 10kw water heater - BRHR Plus 15+water heater Key Features Thin, flat profile is perfect for ceiling mounting. Self-motorized EC fans Aluminum plated, counter-flow heat exchangers with up to 90% high thermal efficiency. Provides up to 85% heat recovery Plug and play electrical connections 100% Summer bypass Highly efficient aluminium heat exchanger Thin, flat profile is perfect for ceiling mounting EC fans with lower power consumptions 2 x G4 filters with side panel allowing easy access for maintenance Weight - 242 kg Technical Features Airflow capacity - 1500 m3h/r @ 100Pa BSK Plus Commercial Heat Recovery units are available with a preheater, post heater or a water heater H x W x D: 450mm x 1200mm x 1550mm 310mm duct connections Optional Accessories Water Heater Pre-Heater Post Heater Control Options Free cooling Boost mode De-frost mode Automated weekly schedules Temperature or humidity trigged automation Boost Mode Boost mode makes the BSK Heat Recovery Unit to run at full capacity in order to quickly ventilate the surroundings. This mode can be triggered in various ways. Built-in humidity sensor can detect the humidity level of the returning air and automatically initiate Boost Mode when a set level of humidity is reached to quickly dissipate the moisture to prevent it building up. Alternatively, if an external aspirator is connectedto the “boost

GBP 5024.76
1

Nuaire Xboxer XBC-65 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-65 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-65 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal) Standard model is available, additional units with extras are available include the electric preheater model and the Low-Pressure Hot Water (LPHW) heater model. Supplied with terminal box for supply and extract fan motor wiring and for interfacing to custom built control panels Nuaire XBC range of high efficiency heat recovery ventilation units designed for ceiling void applications and are suitable for external use with weather roof. Designed to save energy, improve indoor air quality, and provide the lowest noise breakout when used with Nuaire matched attenuators. Please note that all XBC units are supplied as eft hand units as standard, unless otherwise stated on your order. Key Features: High heat exchange efficiency - Up to 95% Low noise Units are aluzinc, asymmetric, high mass, double skinned wall construction with specialist acoustic treatment Compact & flexible - lowest case height (by duty) with unique supply/extract are on unit centreline, intake/extract connections are configurable on site to either side of the unit. Optimum performance – Backward curved impellers and IP54 EC motors provide low specific fan powers and step-less speed control without tonal noise generation. Blowers are ErP 2015 compliant. The unit is designed for side access as standard and must be installed with a minimum of 260mm clearance from a wall or barrier. This will provide access to filters, coil, fan, heat exchanger condensate tray and pump. Technical Features Up to 75% efficient Voltage / Phase / Frequency – 230V / 1 phase / 50 Hz Max operating temperature – 40°C Maximum fan speed (RPM) - 1850 Unit Weight (kg) – 476 Sound level @3m dB(A): 35 – 57 G4 extract and supply filters Counter plate heat exchanger 100% bypass Dimensions (standard model)L x W x D – 1913mm x 1570mm x 624mm

GBP 20293.07
1

BSK Plus 20 Commercial Heat Recovery Unit

BSK Plus 20 Commercial Heat Recovery Unit

BSK Plus 20 Commercial Heat Recovery Unit Product Part Number BSK 2000 m3h/r Horizontal MVHR - digital control - 300mm - BRHR Plus 20 BSK 2000 m3h/r Horizontal MVHR - digital control - 300mm - 6kw pre heater - BRHR Plus 20+pre heater BSK 2000 m3h/r Horizontal MVHR - digital control - 300mm - 14kw post heater - BRHR Plus 20+post heater BSK 2000 m3h/r Horizontal MVHR - digital control - 300mm - 14kw water heater - BRHR Plus 20+water heater Key Features Thin, flat profile is perfect for ceiling mounting. Self-motorized EC fans Aluminum plated, counter-flow heat exchangers with up to 90% high thermal efficiency. Provides up to 85% heat recovery Plug and play electrical connections 100% Summer bypass Highly efficient aluminium heat exchanger Thin, flat profile is perfect for ceiling mounting EC fans with lower power consumptions 2 x G4 filters with side panel allowing easy access for maintenance Technical Features Airflow capacity - 2000 m3h/r @ 100Pa BSK Plus Commercial Heat Recovery units are available with a preheater, post heater or a water heater H x W x L: 540mm x 1450mm x 1650mm 355mm duct connections Optional Accessories Water Heater Pre-Heater Post Heater Control Options Free cooling Boost mode De-frost mode Automated weekly schedules Temperature or humidity trigged automation Boost Mode Boost mode makes the BSK Heat Recovery Unit to run at full capacity in order to quickly ventilate the surroundings. This mode can be triggered in various ways. Built-in humidity sensor can detect the humidity level of the returning air and automatically initiate Boost Mode when a set level of humidity is reached to quickly dissipate the moisture to prevent it building up. Alternatively, if an external aspirator is connectedto the “boost port” of the device, when the aspirator is turned on, the device also enters Boost Mode to help with the

GBP 6336.28
1

BSK Plus 40 Commercial Heat Recovery Unit

BSK Plus 40 Commercial Heat Recovery Unit

BSK Plus 40 Commercial Heat Recovery Unit Product Part Number BSK 4000 m3h/r Horizontal MVHR - digital control - 400mm - BRHR Plus 40 BSK 4000 m3h/r Horizontal MVHR - digital control - 400mm - 10kw pre heater - BRHR Plus 40+pre heater BSK 4000 m3h/r Horizontal MVHR - digital control - 400mm - 23kw post heater - BRHR Plus 40+post heater BSK 4000 m3h/r Horizontal MVHR - digital control - 400mm - 23kw water heater - BRHR Plus 40+water heater Key Features Self-motorized EC fans Provides up to 90% heat recovery Plug and play electrical connections Bypass damper for free cooling Highly efficient aluminium heat exchanger Thin, flat profile is perfect for ceiling mounting ModBus compatible EC fans with lower power consumptions Weight - 366 kg Technical Features Airflow capacity - 4000m3h/r @ 150Pa 2 x G4 filters with side panel allowing easy access for maintenance H x W x D: 667mm x 1650mm x 1850mm 400mm duct connections BSK Plus Commercial Heat Recovery units are available with a preheater, post heater or a water heater Boost mode allows the unit to run at full capacity in order to quickly ventilate the surroundings Boost mode can be triggered in different ways via the built-in humidity sensor or via an external switch Control Options Free cooling Boost mode De-frost mode Automated weekly schedules Temperature or humidity trigged automation Free Cooling Mode During seasonal transitions for example, Spring and Autumn, when indoor and outdoor temperature difference are not signification, the unit automatically switch to Free Cooling Mode by opening the built-in bypass vent. The air will pass through this canal without going through the heat exchanger, thus reducing the stress on fans and operate on an even less power. This set temperature can be changed on the digital control panel to a desired level. Defrost Mode We suggest that you equip a pre-heater for

GBP 8856.68
1

Komfovent RHP-600 4.4/3.8-UV/UH

Komfovent RHP-600 4.4/3.8-UV/UH

Komfovent RHP 600-U Air Handling Unit Product Part Number Komfovent RHP-600V Rotary wheel vertical unit with heat pump - RHP-600 4.4/3.8-UV Komfovent RHP-600H Rotary wheel Horizontal unit with heat pump - RHP-600 4.4/3.8-UH Description Komfovent RHP range are air handling units with an integrated heat pump, this unit features all HVAC systems in one unit providing complete indoor microclimate control. Komfovent RHP 600-U air handling unit provides ventilation in premises up to 400m2. RHP units with heat pump drain. Technical Features Suitable for home sizes up to 375m2 Maximum airflow rate - 650m3/h Weight - 194kg Sound level @ 3m - 41dB(A) Dimensions W x H x D - 1254mm x 878mm x 650mm Duct diameter - 200mm Two Step Heating and Cooling Recovery To reach maximum efficiency these units are designs to recovery energy in two steps Step 1: Recovery by enthalpy rotary heat exchanger Step 2: Recovery by reversible heat pump Cooling Mode Due to cooling recovery by rotary heat exchanger, the air temperature after the rotor is lower than the outside air temperature. Condensation temperature in this case is lower, which results in reduced compressor electricity consumption compared with outdoor condensing unit Heating Mode  a highly efficient rotary heat exchanger is used for first-stage heat recovery, recovering the biggest part of the heat of extracted air. For second-stage heat recovery and supply air temperature control a heat pump is used Controllability Intelligent control with algorithms and reliable components to ensure safe and efficient operation. This unit can be controlled via a digital C5.1 controller Construction RHP units are constructed of galvanized steel sheets, which are powder coated. Mineral wool is used for thermal insulation and sound attenuation. Unit cover panels are 45 mm thick.

GBP 10832.18
1

Vent Axia Integra

Vent Axia Integra

Vent Axia Integra Product Part Number Vent Axia Integra - 456864 Description The Integra heat recovery unit has been specially designed to provide ventilation for flats or rooms in residential, commercial, educational or leisure applications. Balanced ventilation is achieved by using nominal 100mm diameter rigid ducting. Using a high performance, polymeric heat exchange cube, together with two powerful fans, the Vent-Axia Integra achieves efficiency of up to 70%.  The compact cube interleaves outgoing moist air with incoming fresh air, allowing the heat from one to warm the other without the two air streams mixing. Energy is saved on room heating, with no power being used by the cube itself. Filtration Independent filtration is required Controllability The normal unit has two speeds of Boost/Trickle ventilation when used with humidity sensors or a manual wall switch. 95 x 225 x 75mm (H x W x D) An optional 150VA Surface Mounting Transformer is available with six voltage selections for trickle settings to match dwelling volume.  Construction The enclosure is constructed of powder coated galvanised metal Motors The unit has 2 x low energy, high efficiency D/C fan motors Installation The Vent-Axia Integra is designed for mounting in ceiling voids, lofts or above a suspended ceiling. Four 100mm spigots are provided for simple connection to insulated flexible or rigid ventilation ducting. The unit comes complete with a 22mm condensate outlet situated on the base of the unit, this should be connected to a suitable outlet for condensate drainage. Accessories In addition to a choice of compatible ducting systems a full range of controls, sensors, in-line silencers, floor/wall/ceiling inlet and outlet diffusers are available to complete the installation.

GBP 998.40
1

Nuaire Xboxer XBC-25 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-25 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-25 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal) Standard model is available, additional units with extras are available include the electric preheater model and the Low-Pressure Hot Water (LPHW) heater model. Supplied with terminal box for supply and extract fan motor wiring and for interfacing to custom built control panels Nuaire XBC range of high efficiency heat recovery ventilation units designed for ceiling void applications and are suitable for external use with weather roof. Designed to save energy, improve indoor air quality, and provide the lowest noise breakout when used with Nuaire matched attenuators. Please note that all XBC units are supplied as eft hand units as standard, unless other wise stated on your order. Key Features: High heat exchange efficiency - Up to 95% Low noise Units are aluzinc, asymmetric, high mass, double skinned wall construction with specialist acoustic treatment Compact & flexible - lowest case height (by duty) with unique supply/extract are on unit centreline, intake/extract connections are configurable on site to either side of the unit. Optimum performance – Backward curved impellers and IP54 EC motors provide low specific fan powers and step-less speed control without tonal noise generation. Blowers are ErP 2015 compliant. The unit is designed for side access as standard and must be installed with a minimum of 260mm clearance from a wall or barrier. This will provide access to filters, coil, fan, heat exchanger condensate tray and pump. Technical Features Up to 75% efficient Voltage / Phase / Frequency – 230V / 1 phase / 50 Hz Max operating temperature – 60°C Maximum fan speed (RPM) - 3700 Unit Weight (kg) – 242 Sound level @3m dB(A): 40 – 64 G4 extract and supply filters Counter plate heat exchanger 100% bypass Dimensions (standard model)L x W x D – 1700mm x 1150mm x 340mm Benefits of working with BPC Ventilation Number 1 leading MVHR and ventilation system specialists Large range of systems for domestic and commercial applications

GBP 11130.25
1

Nuaire Xboxer XBC-45 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-45 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal)

Nuaire Xboxer XBC-45 Commercial Heat Exchange Unit - (Price Varies Upon Appraisal) Standard model is available, additional units with extras are available include the electric preheater model and the Low-Pressure Hot Water (LPHW) heater model. Supplied with terminal box for supply and extract fan motor wiring and for interfacing to custom built control panels Nuaire XBC range of high efficiency heat recovery ventilation units designed for ceiling void applications and are suitable for external use with weather roof. Designed to save energy, improve indoor air quality, and provide the lowest noise breakout when used with Nuaire matched attenuators. Please note that all XBC units are supplied as eft hand units as standard, unless other wise stated on your order. Key Features: High heat exchange efficiency - Up to 95% Low noise Units are aluzinc, asymmetric, high mass, double skinned wall construction with specialist acoustic treatment Compact & flexible - lowest case height (by duty) with unique supply/extract are on unit centreline, intake/extract connections are configurable on site to either side of the unit. Optimum performance – Backward curved impellers and IP54 EC motors provide low specific fan powers and step-less speed control without tonal noise generation. Blowers are ErP 2015 compliant. The unit is designed for side access as standard and must be installed with a minimum of 260mm clearance from a wall or barrier. This will provide access to filters, coil, fan, heat exchanger condensate tray and pump. Technical Features Up to 75% efficient Voltage / Phase / Frequency – 230V / 1 phase / 50 Hz Max operating temperature – 45°C Maximum fan speed (RPM) - 2400 Unit Weight (kg) – 298 Sound level @3m dB(A): 36 – 59 G4 extract and supply filters Counter plate heat exchanger 100% bypass Dimensions (standard model)L x W x D – 1913mm x 1262mm x 405mm Benefits of working with BPC Ventilation Number 1 leading MVHR and ventilation system specialists Large range of systems for domestic and commercial applications

GBP 11769.79
1

Special Offer Vectaire Maxi AT BY LCDRH Model

Special Offer Vectaire Maxi AT BY LCDRH Model

Description General up to 163 litre/sec at 50Pa - max 177 litre/sec capacity sfp down to 0.40 W/l/s summer bypass which allows the airflow to bypass the heat exchanger automatically when internal and external temperatures are between adjustable setpoints. frost-stat - proportionally reduces intake motor speed as temperature falls - activated when the outside temperature is between +8ºC and -3ºC. run-time and power outage counters easy to install and maintain easy to access G3 filters universal handing for models without humidistat - left or right (see separate diagram for handing on humidistat models) for fitting vertically into lofts, or cupboards - wall fixing bracket supplied variable low (trickle), boost and purge options for each motor boost speed can be activated by a 230V switched live from: a light switch (if more than one light switch is used, each one must be a double pole switch) Remote humidistat (230V - DRH240) Passive infra red (230V - PIRFF) Thermostat (230V - THM) Remote switch/pull cord - 230V low noise levels low running costs CONTROL FEATURES - STANDARD independent variable speed adjustment for each motor for trickle, boost and purge speeds. adjustable boost speed over-run timer from 0 to 30 minutes. adjustable boost speed delay from 0 to 5 minutes remote purge cable connection on circuit board (for optional purge facility) adjustable night time boost and purge inhibitor integral frost-stat - proportionally reduces intake motor speed as temperature falls automatic summer bypass CONTROL FEATURES - FACTORY SET change of ductwork handing on humidistat version (trip point can be set at manufacture) integral humidistat - proportionally increases motor speeds with rising humidity 0-10V connections can be added for: BMS - for remote motor shut-off CO2 detector home automation system relay for external pre-heater 3 speed selector switch optional remote purge cable - factory connected - adjustable over-run timer from 0 to 250 minutes, Pre-set to 15 minutes (adjustable at factory) holiday mode for reduced speeds when property is unoccupied (factory set option) - default setting is 50% of trickle speed run-time and power outage counters downloadable via QR code Specification casing from steel sheet - epoxy paint finish foam construction lining EPS internal components provide acoustic and thermal enhancement low energy EC brushless motor with single width, single inlet, direct drive, forward curved impellors operates in temperature up to 60ºC easy to access standard, disposable G3 filters counter flow heat exchanger Compliance Building Regulations for enhanced energy saving capability Building Regulations for reliable, efficient ventilation EU RoHS Directive Compliant. Complies with IEC60335-2-80, LVD2006/95/CE and EMC2014/30/UE (European Directive against radio interference and electro-magnetic compatibility manufactured in UK to ISO 9001:2015 and 14001:2015 CE marked SAP PCDB Listed Range WHHR Maxi/ BY - bypass, universal WHHR Maxi/ BLH - bypass, left drain humidistat WHHR Maxi/ BRH - bypass, right drain, humidistat Maxi BY+LCD - bypass, universal, integral LCD Maxi+LHHLCD - bypass, left drain, humidistat, integral LCD Maxi+RHHLCD - bypass, right drain, humidistat, integral LC

GBP 1560.00
1

Special Offer Vectaire Maxi BY LCDRH Model

Special Offer Vectaire Maxi BY LCDRH Model

Description General up to 163 litre/sec at 50Pa - max 177 litre/sec capacity sfp down to 0.40 W/l/s summer bypass which allows the airflow to bypass the heat exchanger automatically when internal and external temperatures are between adjustable setpoints. frost-stat - proportionally reduces intake motor speed as temperature falls - activated when the outside temperature is between +8ºC and -3ºC. run-time and power outage counters easy to install and maintain easy to access G3 filters universal handing for models without humidistat - left or right (see separate diagram for handing on humidistat models) for fitting vertically into lofts, or cupboards - wall fixing bracket supplied variable low (trickle), boost and purge options for each motor boost speed can be activated by a 230V switched live from: a light switch (if more than one light switch is used, each one must be a double pole switch) Remote humidistat (230V - DRH240) Passive infra red (230V - PIRFF) Thermostat (230V - THM) Remote switch/pull cord - 230V low noise levels low running costs CONTROL FEATURES - STANDARD independent variable speed adjustment for each motor for trickle, boost and purge speeds. adjustable boost speed over-run timer from 0 to 30 minutes. adjustable boost speed delay from 0 to 5 minutes remote purge cable connection on circuit board (for optional purge facility) adjustable night time boost and purge inhibitor integral frost-stat - proportionally reduces intake motor speed as temperature falls automatic summer bypass CONTROL FEATURES - FACTORY SET change of ductwork handing on humidistat version (trip point can be set at manufacture) integral humidistat - proportionally increases motor speeds with rising humidity 0-10V connections can be added for: BMS - for remote motor shut-off CO2 detector home automation system relay for external pre-heater 3 speed selector switch optional remote purge cable - factory connected - adjustable over-run timer from 0 to 250 minutes, Pre-set to 15 minutes (adjustable at factory) holiday mode for reduced speeds when property is unoccupied (factory set option) - default setting is 50% of trickle speed run-time and power outage counters downloadable via QR code Specification casing from steel sheet - epoxy paint finish foam construction lining EPS internal components provide acoustic and thermal enhancement low energy EC brushless motor with single width, single inlet, direct drive, forward curved impellors operates in temperature up to 60ºC easy to access standard, disposable G3 filters counter flow heat exchanger Compliance Building Regulations for enhanced energy saving capability Building Regulations for reliable, efficient ventilation EU RoHS Directive Compliant. Complies with IEC60335-2-80, LVD2006/95/CE and EMC2014/30/UE (European Directive against radio interference and electro-magnetic compatibility manufactured in UK to ISO 9001:2015 and 14001:2015 CE marked SAP PCDB Listed Range WHHR Maxi/ BY - bypass, universal WHHR Maxi/ BLH - bypass, left drain humidistat WHHR Maxi/ BRH - bypass, right drain, humidistat Maxi BY+LCD - bypass, universal, integral LCD Maxi+LHHLCD - bypass, left drain, humidistat, integral LCD Maxi+RHHLCD - bypass, right drain, humidistat, integral LC

GBP 1320.00
1

BSK NOTUS Multi Orientation Unit with Humidity Sensor

BSK NOTUS Multi Orientation Unit with Humidity Sensor

Description BSK NOTUS/HV/350 The BSK Notus 350 heat recovery unit is a quality MVHR unit manufactured of the latest EPP construction and can installed either vertically or horizontally allowing for almost all site restrictions suitable for new houses up to 225m2 that has advanced Wi-Fi controllability and internal humidity sensor   This unit has a (A) energy rating BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems, Key features- BSK Notus 350 Interactive Wi-Fi Smart Control App Internal humidity sensor Optional touch screen controller Horizontal or Vertical Orientation Electronic orientation change Multiple spigot connections Ultra-Light @ only 18Kg Suitable for home sizes up to 225m2 Airflow rate @100Pa – 375 m3/h EPP Super Quiet construction Highly efficient EC fans 100% summer bypass Fully adjustable fan speeds G4 filtration ‘A’ energy rating High heat recovery efficiency of up to 90%. Optional duct heaters Optional Fire alarm connection Controllability The BSK Notus has advanced controls that allow the user to easily adjust settings Wi-Fi Mobile App The BSK Mobile App is available on iOS and Google Store with the following features Monitor outdoor and indoor temperature and humidity Change fan speeds Control optional heaters Schedule weekly and daily programs Adjust all settings Wall Touch screen controller (optional) 4inch touchscreen Full control of fan speeds Temperature and humidity readings Automatic air quality control with optional AQ sensor. Extensive weekly schedule. Automatic Boost modes External Control The BSK Notus have external connections allowing for hassle free setup Ability to control via a web browser for remote monitoring and repair Integration into a smart home management system. (BMS) via Modbus port Expansion port for bespoke solutions Optional wall controller 0-volt dry boost connection Optional Pre and Post heater connection BMS Control Implemented Modbus protocols enable simple connection into Building Management System as a result whole buildings engineering systems can be controlled at a single access point. Connection and monitoring of multiple units by building managers can be enabled through the BSK Cloud Control Application Construction The BSK Notus is constructed of the latest EPP with a metal front cover EPP (expanded polypropylene) with its lightweight, impact absorbing, and insulating properties make it a perfect body material for MVHR units Motors The fan motors are the latest backward curved low energy EC fans of (A) energy rating Filtration 2 x G4 filters are fitted to the unit that are easy to replace Optional F7 to air supply Summer By-Pass The BSK range of units have a 100% summer by-Pass If the indoor temperature Intake exceeds 25°C and the outdoor temperature is within comfort zones the summer by-pass is opened automatically to help provide a comfortable indoor temperature Low Noise Levels With airtight, aerodynamic and sound absorbing construction with perfectly balanced fans the noise levels are ultra quiet Heat Exchanger Highly efficient PVC counterflow heat exchanger with up to 90% heat recovery Frost Protection Intelligent frost protection is standard on the BSK Notus units Orientation The BSK Notus has multiple configurations and can be electronically changed from Left- and Right-hand orientation Vertical or Horizontal Mounting Left-hand and Right-hand electronic changeover Top and Bottom spigot access Multiple Drain points Mounting The units are supplied with both wall and floor mounting brackets Accessories QV-BoostSw                                       1Gang Momentary Boost Switch NOTUS/W/BLACK/CONTROLLER BSK

GBP 1053.02
1