264 results (0,13988 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vesda VLF-250 LaserFOCUS-250 Detector with Display

Vesda VLF-250 LaserFOCUS-250 Detector with Display

Vesda VLF-250 LaserFOCUS-250 Detector with DisplayThe VESDA VLF-250 detector is a very early warning smoke detector designed to protect small business-critical environments of less than 250 m2 2690 sq. ft..The detector works by continually drawing air into sampling holes in a pipe network. The air is filtered and passed into a detection chamber where light scattering technology detects the presence of very small amounts of smoke.Detector status information is communicated on the detector display and via relays or optional interface cards.Out-of-the-box OperationThe VLF can be installed and commissioned out-of-the-box without the need for a special interface or software programming tools.In operation the unique Smoke DialTM display provides the user with an instant understanding of a smoke event even from a distance. Should a fault occur the user simply opens the field service door and activates the Instant Fault Finder feature to determine the specific fault condition. This information can then be passed onto their fire service company ensuring that service technicians arrive onsite fully prepared.Ultrasonic Flow SensingThe patent-pending Ultrasonic Flow Sensing used in the VLF provides a direct reading of the sampling pipe flow rate. The system is immune to air temperature and pressure changes and is unaffected by contamination. The VLF is the first air sampling smoke detector to use ultrasonic flow sensing.Key FeaturesOut-of-the-Box Installation and CommissioningUltrasonic Airflow SensingLaser-Based Absolute Smoke DetectionPre-engineered pipe network designsProgrammable Alarm ThresholdsClean air barrier optics protectionInstant Recognition DisplayInstant Fault FinderAutoLearn SmokeAutoLearn FlowField Service Access DoorMultiple Event Logging in separate logsEvent log up to 18000 eventsOfflineonline configuration capabilityUp to 250 m2 2690 sq. ft. coverage

GBP 1253.88
1

Elmdene POE-ULTRAPOD-MOD PoE Ultra-Pod Module DIN Rail Mountable Unboxed

Aritech ATS8551 Advisor Multi-client Software - Intro License Key License For 250 Accounts

Vesda Xtralis VPS-250-E5 24V 2A Power Supply Unit 38AHR

Vesda Xtralis VPS-250-E5 24V 2A Power Supply Unit 38AHR

Vesda Xtralis VPS-250-E5 24V 2A Power Supply Unit 38AHRXtralis Power Supply Units are uniquely designed to complement the style and appearance of Xtralis aspirating smoke detectors ASDs and are technically matched to provide sufficient current and battery charging capacity to meet the requirements of EN 54-4. The VPS-250-E5 variant is VdS certified and CE marked to the EN54-4 so is particularly suitable for use in territories where these approvals are required. It may also be suitable in territories where ISO 7240-4 is required.VPS-250-E5 3A load 38Ah batteries maxThis power supply is capable of powering larger ASD units including the VESDA-E VEU at all fan speeds and the VESDA-E VEA detectors. It may also be used for installations with multiple detectors andor remote displays. The internal charger is EN54-4 certified to power loads up to 3A and there is space and charging capacity for batteries up to 38 Ah batteries. Uniquely the unit is supplied with the provision to deliver 4 separately fused outputs recommended when it is used to power multiple detectors or disparate loads. This is a very versatile unit which can deliver to a combined 24Vdc load of up to 3A. The front cover supports 2 LEDs to provide visual indication of Healthy status OK or fault condition and various knockouts exist to provide convenient cabling access to detectors remote displays or subracks. The unit also provides a non-certified setting which enables it to power loads up to 3.4A while recharging batteries up to 38Ah in accordance with EN 54-4.Key FeaturesSupports a 3A load and up to 38Ah batteriesTemperature compensated charging to maximize battery lifeDesigned to blend in with Xtralis detectorsExternal LED indication OK and FaultRelay outputs for connection to the general-purpose input for fault monitoring230Vac only

GBP 468.31
1

Vesda VIC-010 VESDAnet Card for VLF-250 amp VLF-500

Fireclass FC503 3 Loop Panel 250 Points

Fireclass FC503 3 Loop Panel 250 Points

Fireclass FC503 3 Loop Panel 250 PointsThe FC503 is the newest FireClass addressable solution for a wide range of applications and requirements. Conceived to be extremely easy to install and use the FC503 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology. Auto Addressing Intelli-Zone Online Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the panels in just a few simple steps.The FC503 panel has 3 in 1 loops that can support up to 250 addressable devices and 32 zones. The split loop technology enables 3 circuits of devices to be connected to one single loop providing greater flexibility andsimplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 32 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zones re-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extremely user friendly and provides a very nice graphic interface that displays all devices connected to the different zones.A battery and wire calculation tool is included in the software to help the installer in sizing up the system. A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point statusand the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. This new FireClass FC503 control panel supports up to 250 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 loopsUp to 800mA current dynamically shared across 3 loop circuitsAuto mapping with Intelli-Zone featureOnline Help functionUSB interface dual role HostDeviceMulti users and multi installers Up to 2 installers 8 usersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorGSMGPRS as external moduleUp to 8 repeaters and up to 7 FC500 Series panel clientsEvent transmission through PSTN and IPAutomatic drift compensationFast and simple system configuration also offlineTransferable user databaseDevice graphic displayedBattery and wiring calculationCustomizable cables databaseVisualization of all the devices assigned to a single zoneRemote real time visualization of control panel loop and zone status and so on.Easy remote user interface with control buttons reset silence evacuateMultilevel map based on a tree structureAccess device data from any pages of the mapConfiguration downloadable to USB memory stickCapability to print zone label sheet for front panel customization

GBP 722.82
1

Vesda Xtralis VPS-250-STX5 VESDA-E STX PSU 2A 24AH

Vesda Xtralis VPS-250-STX5 VESDA-E STX PSU 2A 24AH

Vesda Xtralis VPS-250-STX5 VESDA-E STX PSU 2A 24AHVESDA-E Power Supply Units are uniquely designed to complement the style and appearance of VESDA-E aspirating smoke detectors ASDs and are technically matched to provide sufficient current and battery charging capacity to meet the requirement of EN 54-4.The STX variants are VdS certified and CE marked to EN54-4 so are particularly suitable for use in territories where these approvals are required. Style STX Product Range Designed with the same widths and styling of the VESDA-E detectors these power supplies geometrically blend with the VESDA-E detectors.They feature the same curved profile and also incorporate an internal channel which accommodates the exhaust of the VESDA-E detectors. This is particularly useful when it is necessary to run the 25mm exhaust pipe back to the protected area back-venting.The units are available in two colours Matt black is standard and works in harmony with the finish of the black plastic VESDA-E detectors the P variants or contrasts with the extruded aluminium finish of other variants.Alternatively the unit can also be supplied with a grey RAL 7047 cover which complements the extruded aluminium finish of the premium VESDA-E Detectors.VPS-250-STX5 VPS250-STX5-SLV 3A load with 24Ah batteries max These are the deeper units designed for installation with a VESDA-E VEU detector at all fan speeds.The internal charger is EN 54-4 certified and is rated to provide a 3A continuous 24Vdc supply. There is space for up to 24Ah batteries not provided.The unit also provides a non-certified setting which enables it to power loads up to 3.4A while recharging batteries up to 24Ah in accordance with EN 54-4.

GBP 449.65
1

Notifier 020-741 IDR-CM Compact Mimic Driver

Carrier UVP-C180 100-180 cm Adjustable Ceiling Mount for UltraView PTZ Dome - Cable Management

Vesda Xtralis VPS-250-STX5-SLV Power Supply 0.5A 24-38AH PSU-STX - Silver

Vesda Xtralis VPS-250-STX5-SLV Power Supply 0.5A 24-38AH PSU-STX - Silver

Vesda Xtralis VPS-250-STX5-SLV Power Supply 0.5A 24-38AH PSU-STX - SilverVESDA-E Power Supply Units are uniquely designed to complement the style and appearance of VESDA-E aspirating smoke detectors ASDs and are technically matched to provide sufficient current and battery charging capacity to meet the requirement of EN 54-4.The STX variants are VdS certified and CE marked to EN54-4 so are particularly suitable for use in territories where these approvals are required. Style STX Product Range Designed with the same widths and styling of the VESDA-E detectors these power supplies geometrically blend with the VESDA-E detectors.They feature the same curved profile and also incorporate an internal channel which accommodates the exhaust of the VESDA-E detectors. This is particularly useful when it is necessary to run the 25mm exhaust pipe back to the protected area back-venting.The units are available in two colours Matt black is standard and works in harmony with the finish of the black plastic VESDA-E detectors the P variants or contrasts with the extruded aluminium finish of other variants.Alternatively the unit can also be supplied with a grey RAL 7047 cover which complements the extruded aluminium finish of the premium VESDA-E Detectors.VPS-250-STX5 VPS250-STX5-SLV 3A load with 24Ah batteries max These are the deeper units designed for installation with a VESDA-E VEU detector at all fan speeds.The internal charger is EN 54-4 certified and is rated to provide a 3A continuous 24Vdc supply. There is space for up to 24Ah batteries not provided.The unit also provides a non-certified setting which enables it to power loads up to 3.4A while recharging batteries up to 24Ah in accordance with EN 54-4.

GBP 481.73
1

Aritech DF950-CM UCM Universal Configuration Module Kit

Carrier FPMA-C100 Flatscreen Ceiling Mount Height 79-129 cm Black - 10-26quot

Vesda Xtralis VIC-020 Multi-Fuctional Control Card VLF for VLF-250 amp VLF-500

Vesda Xtralis VIC-020 Multi-Fuctional Control Card VLF for VLF-250 amp VLF-500

Vesda Xtralis VIC-020 Multi-Functional Control Card VLF for VLF-250 VLF-500The VESDA VLF MCC Multi-function Control Card is an interface card for the range of Xtralis VESDA VLF smoke detectors. An MCC expands the range of input and output communications a VLF detector can perform.Why use a VLF MCCInstalling a VLF MCC into a VLF detector provides a cost-effective solution for customers who need enhanced connectivity fault detection and monitoring and annunciation of alarms and faults. The principal benefits includeImproved FACP connectivityThe VLF is fitted with two 2 alarm relays in its standard form. With an extra two 2 relays the Multi-function Control Card allows reporting of all four 4 alarm levels on dry relay outputs.Enhanced annunciationAn MPO Monitored 24 V Powered Output is available on the VIC-030 version of the card. The MPO provides power to devices such as sirens or strobes and monitors the line integrity.Enhanced control and fault detectionWith a VLF MCC installed a VLF has two 2 General Purpose Inputs GPIs allowing for example one GPI to report on loss of mains power and the other GPI to be used as a reset input. The VIC-030 version of the card has a self-configuring GPI depending on the jumper selection for MPORelay3.If MPO is selected activation of the GPI will disable the MPO.If Relay3 is selected the GPI will be set to External Fault e.g. for mains power supply monitoring.Key FeaturesProvides two 2 additional relaysProvides an extra General-Purpose Input GPI with line monitoringQuick and simple to installOut-of-the-box operation with minimal configuration required for extra featuresDiagnostic LEDs give visual indication of the cards statusFully compatible with Xtralis VESDA VLF smoke detector

GBP 246.11
1

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains Powered

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains Powered

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains PoweredThe ZPR868-CM is a mains powered wireless cluster communicator for interfacing Ziton wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP7 compatible CIE and provides a seamless interface between wireless devices and the CIE.System designA cluster communicator comprises of a radio transceiver capable of communicating with up to 31 wireless devices. Every cluster communicator communicates directly to a ZPR868-H hub or should direct communication not be possible via another cluster communicator with up to 4 hops to the hub. This allows for full meshed networked wireless systems with multiple redundant wireless communication parts as well as longer wireless communication ranges when that is required on large sites.Seamless addition of wireless devicesEvery wireless device controlled through a cluster communicator has its own unique address with which the main fire alarm control panel communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units.Full flexibilityWireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. Cluster communicators allow the system designer full flexibility in selecting the locations of wireless devices anywhere in the system or even allow all the filed devices in system to be wireless up to 508 devices per CIE or 127 devices per loop.Key FeaturesMains supply with battery backup2-Way communication with up to 31 wireless devicesDiversity transceivers allow maximum operational rangeVariable power outputETSI 300-220 approvedEN54-4 18 25 complaint and CPR certified

GBP 364.58
1