Ziton FD-MBP1 Mounting Bracket Prism Ceiling White

Ziton FD-MBP2 Mounting Bracket Prism Ceiling Beige

Ziton ZP2-AF2-99 2 Loop Addressable Fire Panel

Ziton ST801 High Temperature Heat Probe Latched

Ziton ST801 High Temperature Heat Probe Latched

Ziton ST801 High Temperature Heat Probe LatchedThe ST801 and ST802 thermal probe high temperature heat detectors have been designed to protect prom hazards where high temperatures are produced at a specific point. The sensitive element bulb can be set at a distance of up to 1 meter from the connection box.ApplicationsOne of the most common applications for the ST800 is the detection of fires in the extractor cowls of industrial kitchens.The high reliability of thermal probes make them ideal for controlling automatic fire extinguishing systems such as CO2 aerosols etc.For easy adaptation to any monitoring control panels two ST800 models are availableST801The ST801 is a high temperature thermal probe heat detector with a latching relay that maintains the alarm even after the hazard temperature has fallen or disappeared. It may be used as a conventional detector and connected to any of the zones of the fire control panels from Kilsen.ST802The ST802 does not use latching relays. It simply has a potential free relay output allowing for NO COM and NC connections.WarningThe ST800 should not be used to protect large areas. The housing of the unit has not been designed to withstand high temperatures.Key FeaturesCompletely metalAdjustable from 50 to 300 CBack and side cable inputSensitive probe with 1 m of stainless steel capillary pipingResistant to heat grease and humidityEasy installationEasy connectionEasy maintenanceIdeal for commercial areas

GBP 124.19
1

Ziton ST802 High Temperature Heat Probe Unlatched

Ziton ST802 High Temperature Heat Probe Unlatched

Ziton ST802 High Temperature Heat Probe UnlatchedThe ST801 and ST802 thermal probe high temperature heat detectors have been designed to protect prom hazards where high temperatures are produced at a specific point. The sensitive element bulb can be set at a distance of up to 1 meter from the connection box.ApplicationsOne of the most common applications for the ST800 is the detection of fires in the extractor cowls of industrial kitchens.The high reliability of thermal probes make them ideal for controlling automatic fire extinguishing systems such as CO2 aerosols etc.For easy adaptation to any monitoring control panels two ST800 models are availableST801The ST801 is a high temperature thermal probe heat detector with a latching relay that maintains the alarm even after the hazard temperature has fallen or disappeared. It may be used as a conventional detector and connected to any of the zones of the fire control panels from Kilsen.ST802The ST802 does not use latching relays. It simply has a potential free relay output allowing for NO COM and NC connections.WarningThe ST800 should not be used to protect large areas. The housing of the unit has not been designed to withstand high temperatures.Key FeaturesCompletely metalAdjustable from 50 to 300 CBack and side cable inputSensitive probe with 1 m of stainless steel capillary pipingResistant to heat grease and humidityEasy installationEasy connectionEasy maintenancePotential free alarm relay output

GBP 119.74
1

Ziton ZP2-F2-FB2-PRT ZP2 Series Addressable Fire Panel With Fire Brigade Controls And Printer - 2 Loop

Ziton ZP2-F2-FB2-PRT ZP2 Series Addressable Fire Panel With Fire Brigade Controls And Printer - 2 Loop

Ziton ZP2-F2-FB2-PRT ZP2 Series Addressable Fire Panel With Fire Brigade Controls And Printer - 2 LoopThe 2-loop ZP2-F2-FB2-PRT Addressable fire panel with fire brigade controls and printer is a good choice for small to mid-sized addressable applications. Its main controls are clearly yet discreetly highlighted with the focus on the centrally located Jog Dial. With the addressable detection and a full line of easily configured option cards and modules USB and Ethernet connectivity these quick-to-configure systems offer versatility that benefits both building owners and life safety system installers.Key FeaturesThermal printer with paper replacement from the front2 loops expandable to 4 with up to 512 zones with Fire Brigade Fire Protection controls and 300 output groupsUp to 40 LED Zone indicators for Fire and Fault with generous text spaceAuto configuration setup wizard and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesJog Dial with 4 soft buttons for simple and intuitive user controlPleasing design with paintable synthetic doorEasily removable door and chassis for quick and clean installationAll pluggable connectors3 USB ports with memory stick support and RS232 for printer supportEmail notification for events directly from the panel 4 user accountsAuxiliary 24VDC supply output with reset support3 operator level menu structure 20 usernames and passwordsHistory log memory for 9999 eventsUp to 72 hours standby time and 30 minutes alarmCompatible with the new loop powered soundersbeacons and base sounders and the 2000 series detectors with replaceable optical chamber

GBP 1241.38
1

Ziton ZP2-AF1-99 Addressable Fire Panel - 1 Loop - English UK

Ziton ZP2-AF1-99 Addressable Fire Panel - 1 Loop - English UK

Ziton ZP2-AF1-99 Addressable Fire Panel - 1 Loop - English UKThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any dcor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key Features1 High Power Loop with 800 mA per loopUp to 512 zones and 300 output groupsUp to 40 LED Zone indicators for Fire and Fault with ample text spaceAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management software ATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacementCompatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 584.87
1

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24Vdc

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24Vdc

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24VdcThe ZPR868-C is a 24VDC powered wireless cluster communicator for interfacing Ziton wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP7 compatible CIE and provides a seamless interface between wireless devices and the CIE.System designA cluster communicator comprises of a radio transceiver capable of communicating with up to 31 wireless devices. Every cluster communicator communicates directly to a ZPR868-H hub or should direct communication not be possible via another cluster communicator with up to 4 hops to the hub. This allows for full meshed networked wireless systems with multiple redundant wireless communication parts as well as longer wireless communication ranges when that is required on large sites.Seamless addition of wireless devicesEvery wireless device controlled through a cluster communicator has its own unique address with which the main fire alarm control panel communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units.Full flexibilityWireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. Cluster communicators allow the system designer full flexibility in selecting the locations of wireless devices anywhere in the system or even allow all the filed devices in system to be wireless up to 508 devices per CIE or 127 devices per loop.Key Features24VDC supply2-Way communication with up to 31 wireless devicesDiversity transceivers allow maximum operational rangeVariable power outputETSI 300-220 approvedEN54-4 18 25 complaint and CPR certified

GBP 364.58
1

Ziton ZPR868-H Protocol 868Mhz Radio Look Module Hub 4 Loop

Ziton ZPR868-H Protocol 868Mhz Radio Look Module Hub 4 Loop

Ziton ZPR868-H Protocol 868Mhz Radio Look Module Hub 4 LoopThe ZPR868-H is a Ziton protocol radio hub for interfacing up to 4 loops of wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP panel and provides a seamless interface between the panel and the wireless devices.Performance and RangeWith support for smart cluster technology the ZPR868-H provides extended wireless coverage over zone type wireless systems. Diversity antennae allows for extended communication range in all directions whilst multipath communication techniques minimises the risk of interference from external sources.System DesignWith up to 4 hardware loops connected directly from the Ziton fire alarm CIE to the ZPR868-H hub every devices on each of the CIE loops may be connected wirelessly. Cluster communicators ZPR868-C or ZPR868-CM communicate on one side wirelessly to the hub and on the other side to up to 31 wireless devices either detectors notification andor IO units and even other clusters. When redundancy is required multipath communication enables clusters to talk to other clusters to find a reliable communication path back to the hub should its own dual communication frequencies be blocked. Clusters can also communicate with other clusters to extend the wireless communication distance for large installations.Full flexibilityWireless devices are featured in many fire detection and alarm systems and are specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal.Key FeaturesFully loop powered4-Loop connectivity to up to 504 wireless devices2-Way communication with up to 31 wireless clustersDiversity transceivers allow maximum operational rangeVariable power outputUnique multi-path smart cluster technology supportAutomatic selection from 32 radio channels for reliable communication868MHz harmonised frequency supportETSI 300-220 approvedEN54-18 25 complaint and CPR certified

GBP 467.40
1

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains Powered

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains Powered

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains PoweredThe ZPR868-CM is a mains powered wireless cluster communicator for interfacing Ziton wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP7 compatible CIE and provides a seamless interface between wireless devices and the CIE.System designA cluster communicator comprises of a radio transceiver capable of communicating with up to 31 wireless devices. Every cluster communicator communicates directly to a ZPR868-H hub or should direct communication not be possible via another cluster communicator with up to 4 hops to the hub. This allows for full meshed networked wireless systems with multiple redundant wireless communication parts as well as longer wireless communication ranges when that is required on large sites.Seamless addition of wireless devicesEvery wireless device controlled through a cluster communicator has its own unique address with which the main fire alarm control panel communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units.Full flexibilityWireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. Cluster communicators allow the system designer full flexibility in selecting the locations of wireless devices anywhere in the system or even allow all the filed devices in system to be wireless up to 508 devices per CIE or 127 devices per loop.Key FeaturesMains supply with battery backup2-Way communication with up to 31 wireless devicesDiversity transceivers allow maximum operational rangeVariable power outputETSI 300-220 approvedEN54-4 18 25 complaint and CPR certified

GBP 364.58
1

Ziton ZCR868-C Conventional Wireless Communicator

Ziton ZCR868-C Conventional Wireless Communicator

Ziton ZCR868-C Conventional Wireless CommunicatorThe ZCR868-C is a 24VDC powered wireless cluster communicator for interfacing of wireless 868 MHz Ziton fire alarm devices into a conventional ZP fire alarm system. It enables these wireless devices to be controlled and monitored directly from the CIE and provides a seamless interface between wireless devices and the CIE.Wireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. Cluster communicators allow the system designer full flexibility in selecting the locations of wireless devices anywhere in the system.A cluster communicator comprises of a radio transceiver capable of communicating with up to 30 wireless devices. The ZCR868-C communicates directly to a ZCR452 connected to a conventional interface relaying all messages from the wireless field devices.Every wireless device controlled through a cluster communicator has its own unique address with which the cluster communicator communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units and remote indicators.When connected to a conventional interface the specific device message is translated into a general zone message for reporting to the CIE. Mode details including the address of the device and the specific alarm reported are however still available on the LCD display of the ZCR868-C greatly enhancing the diagnostic capabilities of the conventional wireless system.Key Features24VDC operation2-Way communication with up to 30 wireless devicesDiversity transceivers allow maximum operational rangeVariable power outputETSI 300-220 approvedEN54-18 25 complaint and CPR certified

GBP 287.95
1

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors

GBP 564.11
1

Ziton ZR432-2PA Wireless Smoke and Heat Detector with Sounder Base Polar White

Ziton ZR432-2PA Wireless Smoke and Heat Detector with Sounder Base Polar White

Ziton ZR432-2PA Wireless Smoke and Heat Detector with Sounder Base Polar WhiteThe ZR432-2PA is an addressable wireless POLAR WHITE multisensor capable of operating in optical temperature or multisensor modes. In addition it supports an integrated sounder all controlled from the main control panel via a wireless radio interface.Configurable Alarm ResponseDesigned to provide the earliest response to a wide range of fire types in locations where hard wiring is not an option ZR432 detectors combine optical smoke sensing and thermal monitoring to provide an accurate warning of fire. Smoke sensing may be isolated for areas where ambient smoke may exist at certain times of the day or used on a day night basis in premises where heat only is required whilst the building is occupied. Temperature and smoke sensitivity may be set on installation on each device.Device ControlThe ZR432-2PA is supervised and controlled from the main fire panel CIE. Every wireless device is assigned its own IDENT address with which the main control panel communicates providing the same system facilities as directly wired devices.The sounder may be configured during installation for high up to 87 dBA or low up to 74 dBA sound levels with selectable frequencies for two stage tone support both warning and alarm tones. The tones are controlled from the COE in the same way as for hardwired sounders.SupervisionCalibration and self-testing are carried out automatically. Removal or replacement of an incorrect devices is identified by the system and details displayed at the CIE. Sophisticated auto contamination adjustment compensates for any long-term drift in performance caused by dirt entering the sensing chamber.For ease of removal ZR432 detectors plug into the radio base by a simple twist and lock action. A selectable locking mechanism prevents unauthorised removal of the detector from its base.Key FeaturesNo external aerialsDual battery supply with up to 5 year battery lifeFull status monitoring batteries head supervision and tamperConfigurable as smoke only heat only or combination detection2-way wireless communication with variable power outputSounder with configurable tones and volumeSynchronised operationTwo stage evacuation operation supportETSI 300-220 approvedEN54357 and EN5425 compliant and CPR certified

GBP 232.56
1

Ziton ZR432-2PAV Radio Dual Optical Heat Detector with Sounder Base Red Indicator

Ziton ZR432-2PAV Radio Dual Optical Heat Detector with Sounder Base Red Indicator

Ziton ZR432-2PAV Radio Dual Optical Heat Detector with Sounder Base Red IndicatorThe ZR432-2PAV is an addressable wireless POLAR WHITE multisensor capable of operating in optical temperature or multisensor modes. In addition it supports an integrated sounder with visual indicator all controlled from the main control panel via a wireless radio interface.Configurable Alarm ResponseDesigned to provide the earliest response to a wide range of fire types in locations where hard wiring is not an option ZR432 detectors combine optical smoke sensing and thermal monitoring to provide an accurate warning of fire. Smoke sensing may be isolated for areas where ambient smoke may exist at certain times of the day or used on a day night basis in premises where heat only is required whilst the building is occupied. Temperature and smoke sensitivity may be set on installation on each device.Device ControlThe ZR432-2PAV is supervised and controlled from the main fire panel CIE. Every wireless device is assigned its own IDENT address with which the main control panel communicates providing the same system facilities as directly wired devices.The sounder may be configured during installation for high up to 87 dBA or low up to 74 dBA sound levels with selectable frequencies for two stage tone support both warning and alarm tones. The tones are controlled from the COE in the same way as for hardwired sounders. The red 360 visual indicator non EN5423 complaint allows for a 0.5 Hz flash rate and supports the sounder activation for noisy environments.SupervisionCalibration and self-testing are carried out automatically. Removal or replacement of an incorrect devices is identified by the system and details displayed at the CIE. Sophisticated auto contamination adjustment compensates for any long-term drift in performance caused by dirt entering the sensing chamber.For ease of removal ZR432 detectors plug into the radio base by a simple twist and lock action. A selectable locking mechanism prevents unauthorised removal of the detector from its base.Key FeaturesNo external aerialsDual battery supply with up to 5 year battery lifeFull status monitoring batteries head supervision and tamperConfigurable as smoke only heat only or combination detection2-way wireless communication with variable power outputSoundervisual indicator combination with configurable tones and volumeSynchronised operationTwo stage evacuation operation supportETSI 300-220 approvedEN54357 and EN5425 compliant and CPR certified

GBP 318.46
1

Ziton ZP2-AF2-PRT-P 2 Loop Addressable Panel With Integral Thermal Printer

Ziton ZP2-AF2-PRT-P 2 Loop Addressable Panel With Integral Thermal Printer

Ziton ZP2-AF2-PRT-P 2 Loop Addressable Panel With Integral Thermal PrinterThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 1437.30
1

Ziton ZP2-AF2-S 2 Loop Addressable Panel

Ziton ZP2-AF2-S 2 Loop Addressable Panel

Ziton ZP2-AF2-S 2 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2The new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 780.25
1

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2The new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panels supports one network board to create a maximum of 64 nodes 256 loops network of fire panels fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.Approvals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop Up to 512 zones and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 564.11
1

Ziton ZP2-AF2-PRT 2 Loop Addressable Panel With Integral Thermal Printer

Ziton ZP2-AF2-PRT 2 Loop Addressable Panel With Integral Thermal Printer

Ziton ZP2-AF2-PRT 2 Loop Addressable Panel With Integral Thermal PrinterOverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals Compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 1221.61
1

Ziton ZP2-AF2-P 2 Loop Addressable Panel

Ziton ZP2-AF2-P 2 Loop Addressable Panel

Ziton ZP2-AF2-P 2 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 981.05
1

Ziton ZP2-AF2 2 Loop Addressable Panel

Ziton ZP2-AF2 2 Loop Addressable Panel

Ziton ZP2-AF2 2 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 765.35
1

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large Cabinet

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large Cabinet

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large CabinetThe Ziton ZP2-AF2-PRT-99 addressable fire alarm panel with printer has 2 loops that support up to 254 devices each 127 addresses in 512 zones have standard 4 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports an extra 2 loop board that brings the panel to up to 512 zones with 4 additional programmable outputs. Add a network board to create a maximum of 64 nodes 256 loops network of fire panels fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.ZP2-A Panel OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key FeaturesBuild-in thermal printer with paper replacement from the front2 High Power Loop expandable to 4 with 800 mA per loopUp to 512 zones and 300 output groupsUp to 40 LED Zone indicators for Fire and Fault with ample text spaceAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management software ATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacementCompatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 1242.37
1

Ziton ZP2-AF2-S-99 ZP2-A 2 Loop Addressable Fire Panel Small Cabinet

Ziton ZP2-AF2-S-99 ZP2-A 2 Loop Addressable Fire Panel Small Cabinet

Ziton ZP2-AF2-S-99 ZP2-A 2 Loop Addressable Fire Panel Small CabinetThe Ziton ZP2-AF2-S-99 addressable fire alarm panel has 2 loops that support up to 254 devices each 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports an extra 2 loop board that brings the panel to up to 512 zones with 4 additional programmable outputs. Add a network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.ZP2-A Panel OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key Features2 High Power Loop expandable to 4 with 800 mA per loop512 zones and 300 output groupsUp to 24 LED Zone indicators for Fire and Fault with space for a 4 digit numberAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management software ATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacementCompatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 801.02