47 results (0,18352 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton ZR485-3 Wireless Manual Call Point

Ziton ZR485-3 Wireless Manual Call Point

Ziton ZR485-3 Wireless Manual Call PointThe ZR485-3 is a wireless indoor manual call point operating on 868 MHz.System operationThe ZR485-3 is operated either by pressing a resettable element optional or by breaking a frangible glass with finger pressure. The glass element has a clear vinyl coating on the front surface to prevent operator injury and to inhibit the release of loose fragments as the glass is broken. Both operating elements are easily interchangeable.Every wireless device controlled through the RLM interface is assigned its own IDENT address with which the main control panel communicates with it. This provides the same system functionality to wireless as well as traditionally hard-wired devices.Wireless systemsThe ZR485-3 provides a manual means of initiating a fire alarm in areas where the installation of hard wiring is not an option. The unit is controlled from the main fire alarm panel via a loop wired radio interface module. This arrangement allows both wireless and hardwired devices to be seamlessly located on the same loop wiring.The ZR485-3 forms part of an extensive range of wireless fire alarm devices that includes both smokeheat detection as well as notification devices sounderbeacons and IO units.Suitable for use on installations specifying the recommendations of BS 5839 Part 1 the callpoint fully meets the requirements of European Standard EN54 Part 11 and is CPD certified.System testingThe ZR485-3 is designed for surface mounting and is supplied complete with matching back box. System testing is carried out by using a special key supplied with the call point. When inserted into a slot in the base of the call point moulding the device is trigged to operate automatically.Rated at IP42 the ZR485-3 is constructed of ABS plastic and is intended for indoor applications. A red LED indicator prominently positioned on the call point front plate flashes when the unit is operated.Key FeaturesFully addressableFull wireless device status monitoring2-way radio communication5 year battery life at normal conditionsDual battery supply

GBP 142.58
1

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery Pack

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery Pack

Ziton ZR451-3 Radio 868Mhz Input Output Unit with Battery PackThe ZR451-3 is a wireless 868 MHz single channel inputoutput unit. It provides a method of interfacing a supervised input or potential free output signal into and out of the fire detection and alarm system in areas where the installation of system wiring is not an option.The systemThe ZR451-3 communicates with the main control panel via a hardwired radio loop module that can be installed anywhere on the ZP loop. When the input gets an alarm signal it passes it via the radio loop module to the main fire control panel where it is processed. The output of the interface provides volt free change over contacts for connecting ancillary equipment and is programmed separately activated individually on in a group.High intensity LED indicators positioned on the ZR451-3 may be illuminated by a manually activated push button to identify when the interface has operated providing clear identification of the signal source.Installed as part of a ZP addressable system up to 127 line devices sensors call points or interface units may be connected to each of the control panel loops. Each wireless device is assigned its own IDENT address with which the main control panel communicates with it providing the same system facilities as directly wired devices.UsageAs an input the ZR451-3 may receive signals from other alarm equipment e.g. beam detectors aspiration detectors etc. Used as an output the unit switches equipment controlled by the fire detection system e.g. air conditioning systems magnetic door release units etc. Both input and output facilities are available from the same unit and may be operated simultaneously or individually as programmed at the fire control panel.Power supplyThe ZR451-3 is powered by 6 Duracell AA MN1500 LR6 alkaline batteries providing up to 5 years of operational life under normal site conditions. The ZR451-3 features battery condition monitoring and reporting.Key FeaturesAddressable inputoutput interface unitWire free activationVolt free relay outputMonitored input for fire and faultTwo way radio communication

GBP 234.91
1

Ziton ZR4ST-3 ZR4 Series 868 MHz Site Survey Tool for Wireless Installations

Ziton ZR4ST-3 ZR4 Series 868 MHz Site Survey Tool for Wireless Installations

Ziton ZR4ST-3 ZR4 Series 868 MHz Site Survey Tool for Wireless InstallationsThe ZR4ST-3 is a portable radio survey kit to assist in the validation of an 868 MHz wireless fire alarm system prior to installation. A site survey is always required prior to installation for all wireless devices to ensure full system operability after installation.Operating PrincipleFire systems are often required in buildings where cable wiring presents a challenge because the fabric of the building or where the interior design would be negatively affected by the use of cables. It could also be difficult to introduce cable runs into old buildings that were not designed with a modern cable infrastructure. It is in these architecturally sensitive buildings that wireless fire detection is ideal.The ZR4ST-3 survey tool helps establish the viability of a wireless installation in such buildings by allowing a pre-installation survey to be conducted within the standard operating parameters of the system. The ZR4ST-3 confirms the signal strength at every desired location and helps with the overall system design by providing clear go no-go location information.The RangeA typical 868 MHz fire system may consist ofWired or wireless interface modulesWireless fire detectorsWireless notification devicesWireless detectornotification device combinationsWireless manual call pointsWireless inputoutput modulesAll of these require validation for signal strength prior to installation.

GBP 647.00
1

Ziton ZR432-2P Wireless Smoke and Heat Detector with ZR401-3 Base Polar White

Ziton SPB-2P Pluggable Base for ZP755 -2 and -3 Devices Polar White

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3E-03

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3E-03

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3-03ZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan. With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-X3 is a conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.The ZP1-X3E supports class A redundant ring and B standard bus networking with up to 32 nodes including conventional and addressable panels and repeaters via an optional network interface. This allows full remote control and inputs to and from other nodes in the system providing superior flexibility in system organisation and planning.Key FeaturesModern elegant designEasy removable parts for quick and easy installationNormal head-out supervision support per zoneThree detection zones Single zone double zone or any combination of zones configurable for release6 Pre-configured relays and 8 supervised inputs for extinguishing controlConfigurable fire routing sounder extinguishing reset and door monitoring delaysConfigurable Hold Mode type-A or type-B Sounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resettable 24 VDC auxiliary suppliesAuxiliary standard supervised relay output supportDefault support for special functions such as - EN54 compliant user access levels - Basic Advanced level configuration - mixed zones - front panel diagnostics with test disable control - one-man walk testRedundant networking to ZP1 conventional and ZP2 addressable nodesIntrinsically safe and EN54-13 zone support

GBP 376.19
1

Ziton ACA-CE03-100 quotEdgequot Clip Spring Steel 3-8mm 216quot - Pack of 100

Ziton ACA-CE03-025 quotEdgequot Clip Spring Steel 3-8mm 216quot - Pack of 25

Ziton ZR455-3W 868Mhz White Radio Sounder

Ziton ZR455-3W 868Mhz White Radio Sounder

Ziton ZR455-3W 868Mhz White Radio SounderThe ZR455-3W is a WHITE addressable wireless sounder operating on 868 MHz. It is remotely controlled and supervised by an addressable wireless system controller allowing for both wireless and hardwired devices to be seamlessly located on the same fire system. ZR455-3 sounders feature selectable tones for notification of alert evacuate security alert and class change with outputs up to 96 dBA.Highest signal integrityTo ensure the highest signal integrity ZR455-3 sounders transmit and receive statuses and instructions to and from the panel in a multi-path harmonised European 868 MHz band. When installed as part of a ZP addressable fire system where up to 127 device addresses are available per loop up to 62 ZR455-3 devices may be used spread across two radio loop controllers. Every wireless device controlled through the ZPR868 loop interface is assigned its own address with which the main control panel communicates providing the same system facilities as directly wired devices.System designZR455-3 sounders provide notification where the installation of hard wired sounders is not an option. They form part of an extensive range of wireless fire alarm devices that includes audio-visual notification smokeheat detectors manual call points and inputoutput devices.Suitable for applications specifying BS58391 ZR455-3 sounders may be addressed as a standalone units or as part of a group where several units in the same location are synchronized to operate simultaneously. Designed for surface mounting in indoor applications they have no external aerials and are supplied complete with matching back box. The ZR455-3 is rated at IP54 and constructed of ABS plastic.Power supplyPower for the ZR455-3 sounders is derived from two independent and supervised battery sources using standard alkaline batteries allowing up to 5 years of operational life.Key FeaturesFully addressableNo external aerialsWireless range in excess of 150 mTamper supervisionHigh output 32 selectable tones

GBP 215.44
1

Ziton ZR455-3R 868Mhz Red Radio Sounder with Battery Pack

Ziton ZR455-3R 868Mhz Red Radio Sounder with Battery Pack

Ziton ZR455-3R 868Mhz Red Radio Sounder with Battery PackThe ZR455-3R is a RED addressable wireless sounder operating on 868 MHz. It is remotely controlled and supervised by an addressable wireless system controller allowing for both wireless and hardwired devices to be seamlessly located on the same fire system. ZR455-3 sounders feature selectable tones for notification of alert evacuate security alert and class change with outputs up to 96 dBA.Highest signal integrityTo ensure the highest signal integrity ZR455-3 sounders transmit and receive statuses and instructions to and from the panel in a multi-path harmonised European 868 MHz band. When installed as part of a ZP addressable fire system where up to 127 device addresses are available per loop up to 62 ZR455-3 devices may be used spread across two radio loop controllers. Every wireless device controlled through the ZPR868 loop interface is assigned its own address with which the main control panel communicates providing the same system facilities as directly wired devices.System designZR455-3 sounders provide notification where the installation of hard wired sounders is not an option. They form part of an extensive range of wireless fire alarm devices that includes audio-visual notification smokeheat detectors manual call points and inputoutput devices.Suitable for applications specifying BS58391 ZR455-3 sounders may be addressed as a standalone units or as part of a group where several units in the same location are synchronized to operate simultaneously. Designed for surface mounting in indoor applications they have no external aerials and are supplied complete with matching back box. The ZR455-3 is rated at IP54 and constructed of ABS plastic.Power supplyPower for the ZR455-3 sounders is derived from two independent and supervised battery sources using standard alkaline batteries allowing up to 5 years of operational life.Key FeaturesFully addressableNo external aerialsWireless range in excess of 150 mTamper supervisionHigh output 32 selectable tonesAcoustic self testDual battery supply5 year battery life at normal conditionsHarmonised European 868 MHz frequency bandCPD certified

GBP 215.44
1

Ziton Illuminated Warning Sign GRP26-03

Ziton Illuminated Warning Sign GRP26-03

Ziton Illuminated Warning Sign GRP26-03The GRP26-03 optical panel is a low current consumption device using LED technology. The unit also has an internal buzzer with a sound output of 90 dBA to attract additional attention. It offers easy installation and maintenance with a housing of auto-extinguishing plastic material and the possibly to flush mount. The unit is supplied with 3 message inserts Fire Alarm Evacuate Area Immediately and Extinguishing in Progress.InformationThe unit is ideally suited for use with a fire extinguishing control panel. The various text inserts supplied with the unit can be used to supply exact information about the extinguishing process. And this way ensure that people take the correct action in the affected area. It is key that people are not in the area being extinguished as there are various health hazards associate with the various extinguishing agents.FlexibleThe unit offers various flexible options to ensure it is suitable for every application. The unit can be surface mounted of flush mounted with options for cable entry from the back or sides. The 3 different easy changeable text inserts allow for easy customization in the field.Via dip-switch selection the flash frequency of the led illumination can be adjusted or it can be select to have the illumination steady on. Multiple units can also be linked together to ensure synchronization between them.Key FeaturesAesthetic designLow power consumption90dBA ouput levelEasy installationHigh output led illuminationEN54-3 approved

GBP 94.39
1

Ziton FAC355WC VAD Beacon White Deep Base Ceiling Mounted Clear Flash

Ziton AB360 6quot Fire Bell For Indoor Use 24 VDC

Ziton FAC350 VAD Beacon Red Shallow Base Ceiling Mounted Red Flash

Ziton ZR455V-3RR Wireless Red Sounder with Red Beacon

Ziton DC-9103E Conventional Optical Detector Rate of Rise

Ziton ZRC466-3C Wireless Sounder VAD Beacon with Battery Pack Ceiling Mount Red Body White Flash

Ziton ZP720-3P Addressable Heat Detector - Polar White

Ziton 2010-2-PIB-8O Interface Printer Circuit Board with 8 Outputs