16 results (0,14706 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vimpex HS-WLDP Hydrosense HS Conventional Leak Detection Probe

Vimpex IS-L101L-RR IS Intrinsically Safe Beacon - Red

Vimpex IS-L101L-RA IS Intrinsically Safe Beacon - Amber

Vimpex IS-L101L-RG IS Intrinsically Safe Beacon - Green

Vimpex IS-L101L-RB IS Intrinsically Safe Beacon - Blue

Vimpex IS-L101L-RY IS Intrinsically Safe Beacon - Yellow

Vimpex IS-L101L-RC IS Intrinsically Safe Beacon - Clear

Vimpex SL-HDP-JB Signaline HD JB Programmable Linear Heat Cable Junction Box

Vimpex SL-HDP-LHC Signaline HD Programmable Linear Heat Cable - 50m

Vimpex SL-HDP-LHC-N Signaline HD -R Programmable Linear Heat Cable Nylon Coated - 50m

Vimpex FC3EP2 Extinguishant Interface PCB - Two Channel

Vimpex SL-HDP-LHC-S Signaline HD -S Programmable Linear Heat Cable Stainless Steel Braid - 50m

Signaline SLP-001 FT Dual Zone Distance Locator and Monitor

Signaline SLP-001 FT Dual Zone Distance Locator and Monitor

Signaline SLP-001 FT Dual Zone Distance Locator and MonitorThe Signaline SLP-001 LocatorPlus is a combined distance locator and monitor module compatible with all Signaline FT and FT-R linear heatdetection cables.UL approvedthe LocatorPlus gives users instance alarm point location along the Signaline FT linear heat detection cable. However unlike previous locator devices the LocatorPlus can then remotely report this location via the MODBUS output.Furthermore the LocatorPlus can offer location along 2 different zones of Signaline FT cable each upto 3000m long.The LocatorPlus also acts as a monitor module for the linear heat detection. It will report both fire and fault on either zone. These alarms are also indicated via an internal buzzer and LEDs on the LocatorPlus. The LocatorPlus is compatible with any conventional fire detection panel or can operate on an addressable interface. The LocatorPlus can also be used as the activation device on gas releasing panels.The LocatorPlus has two operating modes. Independent mode will report an alarm on either zone of cable independently. However if set to interlocking the alarm relays are not triggered until both zones are in alarm. Thereby removing any risk of false alarms.Key FeaturesModel Signaline LocatorPlus SLP-001Dimensions 180 x 120 x 60.5mm HxWxDIP Rating IP65Finish Light Grey with clear lidDisplay 2 line 16 character backlit display showing zone statusApprovals UL 864 10th ed.Operating voltage 12-36VdcOperating current 12mA 4mAAlarm current 40mA 15mAOperating temp. range -20C 50C -4F 122FTerminal blocks Spacing 5mm Rising ClampRating 16AWire size 0.08mm2 28AWG to 4mm2 11AWGSupervised circuits Power Input Zone 1 Input Zone 2Inputs Up to two zones of Signaline FT or FT-R Linear Heat DetectionZone length 1-3000m 10000ftEnd of Line resistor 1kohm includedShort circuit current 0.5mAMax voltage 5VGround fault impedance 0ohmsCommunications Two wire RS-485 Modbus RTU field wiring limited to same room to comply with UL listingSounder 2.4kHz 92dBa 10cm BuzzerAlarm 2x Form C volt-free relay contacts resistive com-monMax V 30Vac or 42.4VdcMax Current 2A Max Switching Power 60W 62.5VAFault 2x Optoisolated phototransistor output resistive commonMax V 35VdcMax Current 80mA Max Power Dissipation 150mW

GBP 946.61
1

Vimpex ID-WLARI Hydrosense Addressable Remote Indicator

Vimpex SL-HDP-CTL Signaline HD Controller - Programmable Linear Heat Cable Controller

Vimpex SY-GD03 Sav Wire Conventional Sycall Reset Glow Dual Mounting - Green

Vimpex SY-GD03 Sav Wire Conventional Sycall Reset Glow Dual Mounting - Green

Vimpex SY-GD03 Sav Wire Conventional Sycall Reset Glow Dual Mounting - GreenThe Sycall Reset-Glow series of resettable manual call points mimics the feel of breaking glass whilst offering the user benefits and environmental advantages of a resettable operating element. Internal and weatherproof units are available and all variants can be easily identified by an alarm flag which rises into view upon activation. Location assistance is further enhanced by an in-built LED ring which illuminates the central operating window of the Series 01 and 03 units.A special photo-luminescent pigment is also incorporated within the white plastic operating window. In the event of a power failure or reduced light conditions Reset-Glow will remain visible for approximately 5 minutes to assist location for building occupants. The Sycall Reset-Glow provides an ideal solution for most conventional fire alarm systems. It is ideal for industries that are sensitive to broken glass as well as areas that suffer from a high number of false activations such as schools shopping centres and other public places.Key Features Third party tested to EN54-11 Red Series 01 onlyHighly visible during alarm conditionVisible in the dark via the unique luminescent resettable element featureEasy and economical installationHigh impact resistant ABS plastic material - available in Red Blue Green Yellow and WhiteSurface mount and flush mount options availableExtremely easy to reset via the robust twist and set key system

GBP 20.42
1