6 results (0,14769 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vesda Xtralis 25mm Air Sampling Test Point - Pack of 10

Xtralis FLX-020 FAAST FLEX Dual Pipe ASD Unit

Xtralis FLX-020 FAAST FLEX Dual Pipe ASD Unit

Xtralis FLX-020 FAAST FLEXDualPipe ASD UnitXtralis FAAST FLEX offers a highly flexible and cost-effective ASD solution for a wide range of applications such as small to medium warehouses cold storage elevator shafts ceiling and underfloor voids transformer and electrical rooms rest rooms and the like. FAAST FLEX provides consistent detection with minimum nuisance alarms to reduce operational costs enabled by improved detection chamber design.FAAST FLEX allows a high degree of flexibility through pre-engineered pipe network designs and true out-of-the-box operation with a built-in user-friendly configuration and control mechanism. It can be configured and commissioned using a 10-line dip-switch arrangement without the need for a special tool.Through its Bluetooth interface and associated smartphone applications FAAST FLEX offers extended configuration options and rapid diagnostics.FAAST FLEX is easy to install with reduced effort and time 1-man installation with an installation template different orientations direct wall-mounting and ample room for wiring. Through its modular design and field replaceable components FAAST FLEX allows convenient in-field service and maintenance thus minimizing downtime and reducing ongoing maintenance costs.How It WorksAir is drawn into the FAAST FLEX through a network of air sampling pipes by speed adjustable aspirator. Each pipe inlet has an airflow sensor that monitors airflow changes in the pipe. Inside the FAAST FLEX a sample of air is filtered and passed into the detection chamber and analysed for the presence of very small amounts of smoke. Air is exhausted from the FAAST FLEX and may be vented back into the protected zone.Key FeaturesReliable smoke detection for consistent performance and minimum nuisance alarmsSingle Dual channel variants with area coverage up to 1600m 17200 sq.ft for single channel and 2000m 21527 sq.ft for dual channelDouble knock capability Dual Channel for coincident detectionPipe length up to 270m 886 ft for single channel and 420m 1378 ft for dual channel allowing extended coverage and convenient detector mountingClass A B C performance allowing - 1 channel 5 15 32 holes respectively - 2 channels 8 28 56 holes respectivelyAn ultrasonic flow sensing element per chamber for accurate and reliable flow detectionA metallic mesh filter per chamber for optics protection and improved detector longevityAction Alarm and Fault relays per channel for connection to FACP and BMS systemsSimplified and intuitive LEDs user interface for immediate status indicationPre-engineered pipe networks for hassle-free and expedient design and installationTwo configuration modes - Out-of-box with built in user-friendly configuration and control mechanism for speedy commissioning - Extended for enhanced user experienceModular design with in-field replaceable chamber filter and aspirator for ease of service and maintenanceInstallation template different mounting orientations upright inverted and ample wiring room to save time and effortQuiet operation 30db with adjustable fan speed to suit various environmentsSuitable for cold storage environments with -40 C -40F operating temperatureBluetooth interface with mobile device App for extended configuration options and rapid diagnosticsGeneral Purpose Input GPI for remote Reset Disable External FaultPassword protected access for secured detector operation diagnostics and maintenanceIP40 rating for protection against ingress of foreign bodiesOnboard event log up to 2100 events for user actions and smoke trends

GBP 1237.62
1

Xtralis FLX-010 FAAST FLEX Single Pipe ASD Unit

Xtralis FLX-010 FAAST FLEX Single Pipe ASD Unit

Xtralis FLX-010 FAAST FLEX Single Pipe ASD UnitXtralis FAAST FLEX offers a highly flexible and cost-effective ASD solution for a wide range of applications such as small to medium warehouses cold storage elevator shafts ceiling and underfloor voids transformer and electrical rooms rest rooms and the like. FAAST FLEX provides consistent detection with minimum nuisance alarms to reduce operational costs enabled by improved detection chamber design.FAAST FLEX allows a high degree of flexibility through pre-engineered pipe network designs and true out-of-the-box operation with a built-in user-friendly configuration and control mechanism. It can be configured and commissioned using a 10-line dip-switch arrangement without the need for a special tool.Through its Bluetooth interface and associated smartphone applications FAAST FLEX offers extended configuration options and rapid diagnostics.FAAST FLEX is easy to install with reduced effort and time 1-man installation with an installation template different orientations direct wall-mounting and ample room for wiring. Through its modular design and field replaceable components FAAST FLEX allows convenient in-field service and maintenance thus minimizing downtime and reducing ongoing maintenance costs.How It WorksAir is drawn into the FAAST FLEX through a network of air sampling pipes by speed adjustable aspirator. Each pipe inlet has an airflow sensor that monitors airflow changes in the pipe. Inside the FAAST FLEX a sample of air is filtered and passed into the detection chamber and analysed for the presence of very small amounts of smoke. Air is exhausted from the FAAST FLEX and may be vented back into the protected zone.Key FeaturesReliable smoke detection for consistent performance and minimum nuisance alarmsSingle Dual channel variants with area coverage up to 1600m 17200 sq.ft for single channel and 2000m 21527 sq.ft for dual channelDouble knock capability Dual Channel for coincident detectionPipe length up to 270m 886 ft for single channel and 420m 1378 ft for dual channel allowing extended coverage and convenient detector mountingClass A B C performance allowing - 1 channel 5 15 32 holes respectively - 2 channels 8 28 56 holes respectivelyAn ultrasonic flow sensing element per chamber for accurate and reliable flow detectionA metallic mesh filter per chamber for optics protection and improved detector longevityAction Alarm and Fault relays per channel for connection to FACP and BMS systemsSimplified and intuitive LEDs user interface for immediate status indicationPre-engineered pipe networks for hassle-free and expedient design and installationTwo configuration modes - Out-of-box with built in user-friendly configuration and control mechanism for speedy commissioning - Extended for enhanced user experienceModular design with in-field replaceable chamber filter and aspirator for ease of service and maintenanceInstallation template different mounting orientations upright inverted and ample wiring room to save time and effortQuiet operation 30db with adjustable fan speed to suit various environmentsSuitable for cold storage environments with -40 C -40F operating temperatureBluetooth interface with mobile device App for extended configuration options and rapid diagnosticsGeneral Purpose Input GPI for remote Reset Disable External FaultPassword protected access for secured detector operation diagnostics and maintenanceIP40 rating for protection against ingress of foreign bodiesOnboard event log up to 2100 events for user actions and smoke trends

GBP 966.89
1

Vesda Xtralis PIP-015 Flush Sample Point Head Only for 10mm OD Tube

Vesda Xtralis PIP-015 Flush Sample Point Head Only for 10mm OD Tube

Vesda Xtralis PIP-015 Flush Sample Point Head Only for 10mm OD TubeDue to the aesthetic design of some buildings such as ornate ceilings or ceiling art-work a discreet unobtrusive smoke detection system is often desirable. Large open atria or voids feature stratified thermal layers that can prevent cooled smoke from reaching ceiling level. As such conventional systems will normally only respond when a fully-fledged fire condition is reached by which time significant damage has already occurred.VESDA provides the discreet detection required in heritage buildings by routing the sampling pipes in areas that are not visible from normal occupancy. Small-bore capillary pipes are used to provide detection at the required location. The room fabric often dictates the location of these capillary tubes. Hiding the capillary tubes behind light fittings blending in with ceiling paintings or forming part of the ceiling sculptures can all be used to provide invisible smoke detection. In high volume atria applications such as cathedrals capillary sample points can be routed into the area at intermediate vertical levels to good effect to overcome stratification. The higher potential sensitivity of the VESDA system means that less smoke is required at the sample points to provide an alarm condition.With over 250000 aspirating smoke detectors installed worldwide the VESDA name has become synonymous with high quality and outstanding performance. An aspirating smoke detection system however only performs at its best with a well designed and installed quality pipework system. Xtralis manufacturer of VESDA detectors recognised this requirement and in 1997 launched its VESDA Pipe and Fittings range.Key FeaturesFor use with Red or White ABSOperating temperature range -40C to 70CLPCB approvedEN54 testedApplications Used inChurchesHospitalsMuseums GalleriesPrisonsLibrariesArchivesConcert HallsPlease Note The PIP-015 is equivalent to the REDASP025F.

GBP 9.07
1

Vesda-E VES VES-A00-P Aspirating Smoke Detector with LEDs

Vesda-E VES VES-A00-P Aspirating Smoke Detector with LEDs

Vesda-E VES VES-A00-P Aspirating Smoke Detector with LEDsThe VESDA-E VES can identify and monitor smoke density by individual sampling pipe sector which allows a single zone to be divided into four separate sectors for example distinguishing between separate aisles within a data room. Sector addressability enables the user to respond to a potential fire event quickly by reducing the search area. The VESDA-E VES has four programable alarm thresholds Alert Action Fire 1 and Fire 2 per pipe that allows flexible field application. After the detector identifies the first sector to reach the Alert threshold it continues to sample from all sectors to report real time status per sector via the intuitive touch screen display. Built on the Flair detection technology and years of application experience the VESDA-E VES detector delivers very early warning with the best in class dust rejection throughout its lifetime.The VESDA-E is the most advanced reliable and flexible ASD system ever produced.Key FeaturesSector addressability for up to four sectors or zonesAdaptive scan thresholdFlair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarmsMulti stage filtration and optical protection with clean air barriers ensures lifetime detection performanceFour configurable alarm levels per sector and a wide sensitivity range deliver optimum protection for the widest range of applicationsIntuitive LCD display provides instant status information for immediate responseFlow fault thresholds per port accommodate varying airflow conditionsSmart on-board filter retains dust count and remaining filter life for predictable maintenanceExtensive event log 20000 events for event analysis and system diagnosticsAuto Learn smoke and flow for reliable and rapid commissioningBackward compatible with VLS and VESDAnetEthernet for connectivity with Xtralis software for configuration secondary monitoring and maintenanceSecondary monitoring and maintenance via WiFiUSB for PC configuration and firmware upgrade using a memory stickTwo programmable GPIs 1 monitored for flexible remote controlField replaceable sub-assemblies enable faster service and maximum uptime

GBP 4964.20
1

Vesda-E VES VES-A10-P Aspirating Smoke Detector with 3.5 Display

Vesda-E VES VES-A10-P Aspirating Smoke Detector with 3.5 Display

Vesda-E VES VES-A10-P Aspirating Smoke Detector with 3.5 DisplayThe VESDA-E VES can identify and monitor smoke density by individual sampling pipe sector which allows a single zone to be divided into four separate sectors for example distinguishing between separate aisles within a data room. Sector addressability enables the user to respond to a potential fire event quickly by reducing the search area. The VESDA-E VES has four programable alarm thresholds Alert Action Fire 1 and Fire 2 per pipe that allows flexible field application. After the detector identifies the first sector to reach the Alert threshold it continues to sample from all sectors to report real time status per sector via the intuitive touch screen display. Built on the Flair detection technology and years of application experience the VESDA-E VES detector delivers very early warning with the best in class dust rejection throughout its lifetime.The VESDA-E is the most advanced reliable and flexible ASD system ever produced.Key FeaturesSector addressability for up to four sectors or zonesAdaptive scan thresholdFlair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarmsMulti stage filtration and optical protection with clean air barriers ensures lifetime detection performanceFour configurable alarm levels per sector and a wide sensitivity range deliver optimum protection for the widest range of applicationsIntuitive LCD display provides instant status information for immediate responseFlow fault thresholds per port accommodate varying airflow conditionsSmart on-board filter retains dust count and remaining filter life for predictable maintenanceExtensive event log 20000 events for event analysis and system diagnosticsAuto Learn smoke and flow for reliable and rapid commissioningBackward compatible with VLS and VESDAnetEthernet for connectivity with Xtralis software for configuration secondary monitoring and maintenanceSecondary monitoring and maintenance via WiFiUSB for PC configuration and firmware upgrade using a memory stickTwo programmable GPIs 1 monitored for flexible remote controlField replaceable sub-assemblies enable faster service and maximum uptime

GBP 5292.54
1