25 results (0,14999 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kidde 1-B6782-190 EExe GRP Junction Box For Tank Top Cw 3 Cable Glands

GBP 307.34
1

Kidde 1-23911-K069 FireBeta XT Extinguishing Control Panel 3 Zone 1 Area

Kidde 1-23911-K069 FireBeta XT Extinguishing Control Panel 3 Zone 1 Area

Kidde 1-23911-K069 FireBeta XT Extinguishing Control Panel 3 Zone 1 AreaFireBeta XT extinguishing control panels are designed andmanufactured to the highest standards in a quality controlledenvironment. With its EN12094-1 approvals it offers outstanding valueand performance for small to medium sized fixed firefightinginstallations.The FireBeta XT is supplied in an enclosure that matchesthe design and colour of the status unit range.The 3 detection zone circuits allow extinguishing agent release to beconfigured to activate from any combination of detection zones. Thisallows among others any 2 zones from the combination of 3 toactivate release making it ideal for applications protecting ceilingroom and floor voids.The extensive configuration options of the FireBeta XT allow thefunctionality of the system to be extensively modified to suit theapplication while still complying with EN12094-1 EN54-2 and EN54-4.A large LED display on the panel fascia enables easy configurationand control. It additionally displays the time remaining untilextinguishing agent release for added user safety.The control panel status can be displayed on up to 7 remote statusindicators. This allows the agent release status to be displayed at fore.g. multiple entrances to a protected area adding additional usersafety. The communication between the panel and its status indicatorsis fully monitored.The internal electronics are mounted on a single easily removablesteel plate making the FireBeta XT robust and easy to install.Key FeaturesEN12094-1 EN54-2 and EN54-4 approvedThree detection zones as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage sounder delaysConfigurable detection delaysZero time delay for manual release optionCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems e.g. aspiration systems Configurable extinguishing agent delays up to 60 seconds in 5 second stepsCountdown timer shows time remaining until releaseSupports up to seven four wire status indicatorsBuilt in extract fan control

GBP 509.66
1

Kidde NC-PX3 Conventional Fire amp Extinguishing Panel With UI - 3 Zone

Kidde NC-PX3 Conventional Fire amp Extinguishing Panel With UI - 3 Zone

Kidde NC-PX3 Conventional Fire Extinguishing Panel With UI - 3 ZoneThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PX3 is a conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantKey FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and easy installationNormal head-out supervision support per zoneThree detection zonesSingle zone double zone or any combination of zones configurable for release6 Pre-configured relays and 8 supervised inputs for extinguishing controlConfigurable fire routing sounder extinguishing reset and door monitoring delaysConfigurable Hold Mode type-A or type-BSounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resettable 24 VDC auxiliary supplyAuxiliary standard supervised relay output supportDefault support for special functions such as - EN54 compliant user access levels - Basic Advanced level configuration - mixed zones - front panel diagnostics with test disable control - one-man walk test

GBP 349.60
1

Kidde 1X-X3E-99 Conventional Fire amp Extinguishing Panel With UI - 3 Zone - Full Opt Eng Int

Kidde 1X-X3E-99 Conventional Fire amp Extinguishing Panel With UI - 3 Zone - Full Opt Eng Int

Kidde 1X-X3E-99 Conventional Fire Extinguishing Panel With UI - 3 Zone - Full Opt Eng IntThe 1X-X3E-99 is a networkable enhanced conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.The 1X fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any dcor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking black lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs. The 1X-X3E supports class A redundant ring and B standard bus networking with up to 32 nodes including conventional and addressable panels and repeaters via an optional network interface. This allows full remote control and inputs to and from other nodes in the system providing superior flexibility in system organization and planning.Key FeaturesSounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resettable 24 VDC auxiliary supplyAuxiliary standard supervised relay output supportIntrinsically safe and EN54-13 zone support

GBP 412.79
1

Kidde ACA-CE03-100KIT LHD Cable Accessory - Clip quotEdgequot 3-8mm 216quot W Sleeve 100 Pack

Kidde NC-PX3E Conventional Fire amp Extinguishing Panel With UI - 3 Zone - Full Opt

Kidde NC-PX3E Conventional Fire amp Extinguishing Panel With UI - 3 Zone - Full Opt

Kidde NC-PX3E Conventional Fire Extinguishing Panel With UI - 3 Zone - Full OptThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PX3E is a networkable enhanced conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.The NC-PX3E supports class A redundant ring and B standard bus networking with up to 32 nodes including conventional and addressable panels and repeaters via an optional network interface. This allows full remote control and inputs to and from other nodes in the system providing superior flexibility in system organisation and planning.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantKey FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and easy installationNormal head-out supervision support per zoneThree detection zonesSingle zone double zone or any combination of zones configurable for release6 Pre-configured relays and 8 supervised inputs for extinguishing controlConfigurable fire routing sounder extinguishing reset and door monitoring delaysConfigurable Hold Mode type-A or type-BSounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resetable 24 VDC auxiliary supplyAuxiliary standard supervised relay output supportDefault support for special functions such as - EN54 compliant user access levels - Basic Advanced level configuration - mixed zones - front panel diagnostics with test disable control - one-man walk testRedundant networking to 1X conventional and 2X addressable nodesIntrinsically safe and EN54-13 zone support

GBP 478.92
1

Kidde N-MC-BS Anti-Tamper Breakable Seal For Manual Call Points

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control PanelThe Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel is a ULFM listed extinguishing control panel designed and manufactured to the highest standards in a quality controlled environment. With UL and FM approvals it offers outstanding value and performance for small to medium sized fixed firefighting installations. FireBeta A-XT is supplied in a red enclosure.The 3 initiation circuits allow extinguishant release to be configured to activate from any combination of detection zone inputs. This allows among others any 2 zones from the combination of 3 to activate release making it ideal for applications protecting ceiling room and floor voids.The extensive configuration options of the FireBeta A-XT allow the functionality of the system to be extensively modified. A large LED display on the panel fascia enables easy configuration and control. It additionally displays the time remaining until extinguishing agent release for added user safety.Key FeaturesUL864 and FM listedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stepsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining to releaseSupports up to seven four wire status indicatorsBuilt in extract fan control

GBP 536.48
1

Kidde Airsense Wire Burn Test Rig 9-30051

Kidde Airsense Stratos-HSSD 2 Standard Detector 9-30621

Kidde Airsense Stratos-HSSD 2 - Minimum Display Version 9-30710

Kidde Airsense Command Module Without Stratos-HSSD 2

Kidde Airsense Stratos-HSSD 2 Detector Fitted With Command Module 9-30620

Kidde Airsense EST-DFMS Fireman Microphone

Kidde Airsense EST-DFMS Fireman Microphone

Kidde Airsense EST-DFMS Fireman MicrophoneA EST ENT VES fireman microphone is a monitored external device working with Control Units in a redundant communication ring. It can thereby perform a superior function of a system control unit too.A fireman microphone can be used to activate alarm messages as well as general public announcements to choose individual zones and to broadcast live voice messages. It is equipped with programmable function keys which can be used to assign functions as required. Up to 5 EST-EKB-20M keyboard extensions with additional function keys can be attached to a fireman microphone.A CPU switch enables immediate and direct broadcasting of announcements to all zones without any involvement of the control system even during a failure of the central processor. The microphone is able to automatically detect a key failure and an audio path from the microphone capsule inclusive to the Control Unit. A fireman microphone is also equipped with an intercom function and is able to communicate with other microphones in the system.Key FeaturesMonitored microphone and connection of the microphone module to the systemA dedicated evacuation key 3 fully-programmable keys with a possibility of connecting up to five 20-key extensionsBuilt-in 2 contact inputs and 2 relay outputsPOE or external feeder-based power supplyBlack-box function recording all announcements played during an alarmBuilt-in SFP modules and CAT5e for simplicity of implementation of the loop topologyRS485 for communication with external systemsIntercom function between all fireman and zone microphones

GBP 1256.28
1

Kidde 1-23911-K070 Firebeta XT Ancillary PCB

Kidde 1-23911-K070 Firebeta XT Ancillary PCB

Kidde 1-23911-K070 Firebeta XT Ancillary PCBThe Kidde 1-23911-K070 FireBeta XT Ancillary PCB is an accessory to the EN approved FireBeta XTXT extinguishing control panels. These ancillary boards extend the signals from the extinguishing system to other control or signalling equipment e.g. the building management BMS or other fire alarm systems that may be present in the building.Up to 7 ancillary boards can be connected to the FireBeta XTXT control panel via a fully monitored RS485 communication link. This allows for the same signalling capabilities at multiple locations up to 1200 m away from the main control panel.Every ancillary board is provided with 10 potential free changeover contact outputs each allocated to a specific extinguishing system function. On board status LEDs are provided to indicate the status of each output. These LEDs illuminate when the output is active.Ancillary boards may be mounted inside the extinguishing control panel cabinet or remotely in external enclosures. Every ancillary board is given a unique address to enable accurate location reporting of communication faults between the panel and the board.Supported Output FunctionsThe following area status can be signalledZone 1 fireZone 2 fireZone 3 fireManual only mode activatedDisablement activeGas release confirmationExtinguishing release countdown activatedManual release operatedExtract fan output operatedHold circuit activatedKey FeaturesPotential free contacts for remote signalling of extinguishing system statusSupervised 2-wire RS485 data connectionUp to 7 boards per systemLED indicators confirm relay operationMay be mounted inside the extinguishing panel cabinet or remotely

GBP 195.72
1

Kidde 1-23911-K090 FireBeta XT 4 Zone 1 Area Control Panel

Kidde 1-23911-K090 FireBeta XT 4 Zone 1 Area Control Panel

Kidde 1-23911-K090 FireBeta XT 4 Zone 1 Area Control PanelKidde 1-23911-K090 FireBeta XT extinguishing control panels are designed and manufactured to the highest standards in a quality controlled environment. With its EN12094-1 approvals it offers outstanding value and performance for small to medium sized fixed firefighting installations. The Kidde 1-23911-K090 FireBeta XT is supplied in an enclosure that matches the design and color of the status unit range.The 4 detection zone circuits allow extinguishing agent release to be configured to activate from any combination of detection zones. This allows among others any 2 zones from the combination of 3 to activate release making it ideal for applications protecting ceiling room and floor voids.The extensive configuration options of the FireBeta XT allow the functionality of the system to be extensively modified to suit the application while still complying with EN12094-1 EN54-2 and EN54-4. A large LED display on the panel fascia enables easy configuration and control. It additionally displays the time remaining until extinguishing agent release for added user safety.The control panel status can be displayed on up to 7 remote status indicators. This allows the agent release status to be displayed at for e.g. multiple entrances to a protected area adding additional user safety. The communication between the panel and its status indicators is fully monitored.The internal electronics are mounted on a single easily removable steel plate making the FireBeta XT robust and easy to install.Key FeaturesWalk test modeTwo first stage sounder outputsOne second stage sounder outputFirst stage relay contactSecond stage relay contactAuxiliary 24V DC outputMonitored manual release inputMonitored extinguishant outputMonitored Released pressure switch inputMode select keyswitch on front panel optionalManual release on front panel optional

GBP 1983.86
1

Kidde NC-PF4 Conventional Fire Panel With UI - 4 Zone

Kidde NC-PF4 Conventional Fire Panel With UI - 4 Zone

Kidde NC-PF4 Conventional Fire Panel With UI - 4 ZoneThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PF4 is a conventional fire alarm control panel. It is supplied with 4 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24 VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMeAuxiliary standard supervised relay output boardsNetworkable up to 64 zonesNo language kit inserts required

GBP 237.89
1

Kidde NC-PF8 Conventional Fire Panel With UI - 8 Zone

Kidde NC-PF8 Conventional Fire Panel With UI - 8 Zone

Kidde NC-PF8 Conventional Fire Panel With UI - 8 ZoneThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PF8 is a conventional fire alarm control panel. It is supplied with 8 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24 VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMeAuxiliary standard supervised relay output boardsNetworkable up to 64 zonesNo language kit inserts required

GBP 317.26
1

Kidde NC-PF4-SC Conventional Fire Panel With UI amp Scandinavian Key - 4 Zone

Kidde NC-PF4-SC Conventional Fire Panel With UI amp Scandinavian Key - 4 Zone

Kidde NC-PF4-SC Conventional Fire Panel With UI Scandinavian Key - 4 ZoneThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any decor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The PanelThe NC-PF4-SC is a conventional fire alarm control panel with Scandinavian key support. It is supplied with 4 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedNEN2535 NBNS21-100 and BS5839-1 compliantWEEE compliantRoHS compliantType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMeAuxiliary standard supervised relay output boardsNetworkable up to 64 zonesNo language kit inserts required

GBP 237.89
1

Kidde Airsense EST-CU-8LCD Control Unit - 8 Control Slots 4 Function Slots

Kidde Airsense EST-CU-8LCD Control Unit - 8 Control Slots 4 Function Slots

Kidde Airsense EST-CU-8LCD Control Unit - 8 Control Slots 4 Function SlotsESTCU-8LCD Control Unit CU is a matrix mixer of input signals which routes to 4 x 100 V internal audio buses a 45-channel digital system buses or directly to audio outputs in a unit.In basic factory configuration EST-CU-8LCD is a stand-alone system which enables only connections with DFMS and zone microphones.For networking with other CU optional xNet card is needed.The CU is equipped with 1x EST-xCtrLine-4 card in slot 1 1x ESTAudIO-48-RS card in slot A and 1x EST-LogIN-8f card in slot B. Slot C and D can extend control unit audio dsp abilities up to 24 audio outputs 12 audio inputs. Slots from 2 to 7 are free for any cards assignment EST-xCtrLine-24 and EST-xLogINOUT.Furthermore EST-CU-8LCD is equipped with an LCD touch screen with a control module which allows easy access to management functions and monitoring of the whole system.Key Features Network-based system allowing configuration diagnostics and management via EthernetManaging up to 254 devices on the network7 slots available for any configuration of loudspeaker control cards control input and output cardsAdditional 2 slots designated for audio inputoutput cards and control input output cardsUp to 8 messages played simultaneously in different zonesUp to 32GB SD flash memory designated for playback and recording messages 48 kHz 16 bitSupport of up to 12 secured amplifiersOptional equipment EST-xNET-1GbWANRS for optical fibre redundant connectionIntegrated DSP with implemented 3 band parametric EQ on all inputs on control units 8 band parametric EQ delay lines audio limiter and feedback eliminator on each of the audio outputsComprehensive solution based on RS485 functionality enabling seamless integration of the EST ENT VES system with 3rd party systems thanks to implementation of standard and proprietary communication interfaces

GBP 1953.20
1

Kidde NC-PF2 Conventional Fire Panel With UI - 2 Zone

Kidde NC-PF2 Conventional Fire Panel With UI - 2 Zone

The New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PF2 is a conventional fire alarm control panel. It is supplied with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.No Language Kit required for localization.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24 VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMeAuxiliary standard supervised relay output boardsNetworkable up to 64 zonesNo language kit inserts required

GBP 226.60
1

Kidde NC-PF2-SC Conventional Fire Panel With UI amp Scandinavian Key - 2 Zone

Kidde NC-PF2-SC Conventional Fire Panel With UI amp Scandinavian Key - 2 Zone

Kidde NC-PF2-SC Conventional Fire Panel With UI Scandinavian Key - 2 ZoneThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any decor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The PanelThe NC-PF2-SC is a conventional fire alarm control panel with Scandinavian key support. It is supplied with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedNEN2535 NBNS21-100 and BS5839-1 compliantWEEE compliantRoHS compliantType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMeAuxiliary standard supervised relay output boardsNetworkable up to 64 zonesNo language kit inserts required

GBP 226.60
1

Kidde Airsense EST-CU-11LT Control Unit 11 control slots

Kidde Airsense EST-CU-11LT Control Unit 11 control slots

Kidde Airsense EST-CU-11LT Control Unit 11 control slotsESTCU-11LT Control Unit CU is a matrix mixer of input signals which routes to 4 x 100 V internal audio buses a 45-channel digital system buses or directly to audio outputs in a unit. EST-CU-11LT is designed to work for small PA VE systems or as an extension unit in more complex systems. It means that the CU can function independently as the central unit of a small system or be part of a large complex system for which it represents another level of either territorial extension operation in a remote structure or functional extension operation of further fire zones and loudspeaker lines in such a structure.The modular design of the CU and its flexibility enables optimization of equipment and cost efficiency regardless of size number of structures their location and connectivity.In the event of losing connectivity with a networked master unit ESTCU-11LT is able to perform fire alarm scenarios independently thanks to the configuration recorded locally. While attached to the main communication ring of the system EST-CU-11LT can control amplifiers and power supply managers as well as receive alarm and digital signals and send them to other system devices.EST-CU-11LT Control Unit distributes audio signals to individual zones and ensures that individual zones function properly. It also controls the condition of loudspeaker lines and amplifiers.If a fault is detected it sends the signal to the system and automatically switches to a backup amplifier. The CU is equipped with an EST-cAudIO-412 card offering 4 symmetrical line audio inputs and 12 symmetrical outputs to lead audio signals out to external devices or amplifiers of the EST ENT VES system.Key FeaturesCompliance with EN54-16Network-based system allowing configuration diagnostics andmanagement via EthernetManaging up to 254 devices on the network11 slots available for any configuration of loudspeaker control cards andcontrol input output cardsBuilt-in audio card with 4 inputs and 12 audio outputsUp to 12 messages played simultaneously in different zonesUp to 32 GB SD flash memory designated for playback and recordingmessages 48 kHz 16 bit1x POE portSupport of up to 12 secured amplifiersBuilt-in 2 control inputs and outputs2x 1 GB ports available for system extensionIntegrated DSP with implemented 3 band parametric EQ on all inputs oncontrol units 8 band parametric EQ delay lines audio limiter andfeedback eliminator on each of the audio outputsComprehensive solution based on RS485 functionality enablingseamless integration of the EST ENT VES system with 3rd partysystems thanks to implementation of standard and proprietarycommunication interfaces

GBP 1823.00
1

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slots

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slots

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slotsESTCU-11LT Control Unit CU is a matrix mixer of input signals which routes to 4 100 V internal audio buses a 45-channel digital system buses or directly to audio outputs in a unit.EST-CU-11LT is designed to work for small PA VE systems or as an extension unit in more complex systems.It means that the CU can function independently as the central unit of a small system or be part of a large complex system for which it represents another level of either territorial extension operation in a remote structure or functional extension operation of further fire zones and loudspeaker lines in such a structure.The modular design of the CU and its flexibility enables optimization of equipment and cost efficiency regardless of size number of structures their location and connectivity. In the event of losing connectivity with a networked master unit ESTCU-11LT is able to perform fire alarm scenarios independently thanks to the configuration recorded locally. While attached to the main communication ring of the system EST-CU-11LT can control amplifiers and power supply managers as well as receive alarm and digital signals and send them to other system devices.EST-CU-11LT Control Unit distributes audio signals to individual zones and ensures that individual zones function properly. It also controls the condition of loudspeaker lines and amplifiers. If a fault is detected it sends the signal to the system and automatically switches to a backup amplifier.The CU is equipped with an EST-cAudIO-412 card offering 4 symmetrical line audio inputs and 12 symmetrical outputs to lead audio signals out to external devices or amplifiers of the EST ENT VES system. Furthermore EST-CU-11LT can be equipped with an LCD touch screen with a control module which allows easy access to management functions and monitoring of the whole system such extended configuration is included in EST-CU-11LCD Control Unit.Key FeaturesCompliance with EN54-16Network-based system allowing configuration diagnostics andmanagement via EthernetManaging up to 254 devices on the network11 slots available for any configuration of loudspeaker control cards andcontrol input output cardsBuilt-in audio card with 4 inputs and 12 audio outputsUp to 12 messages played simultaneously in different zonesUp to 32 GB SD flash memory designated for playback and recordingmessages 48 kHz 16 bit1x POE portSupport of up to 12 secured amplifiersBuilt-in 2 control inputs and outputs2x 1 GB ports available for system extensionIntegrated DSP with implemented 3 band parametric EQ on all inputs oncontrol units 8 band parametric EQ delay lines audio limiter andfeedback eliminator on each of the audio outputsComprehensive solution based on RS485 functionality enablingseamless integration of the EST ENT VES system with 3rd partysystems thanks to implementation of standard and proprietarycommunication interfaces

GBP 2213.64
1