22 results (0,14217 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Gent 14111-99 1102 Round Call Point Glass Pack of 10

Gent 14112-09 Square Replacement Glass - BS5839 Version Pack of 10

Gent Vigilon Plus Repeater Panel

Gent VIGPLUS-72 Vigilon Plus 1-6 Loop Control Panel with 1 Loop Card

Gent VIGPLUS-72 Vigilon Plus 1-6 Loop Control Panel with 1 Loop Card

GentVIGPLUS-72Vigilon Plus 1-6 Loop Control Panel with 1 Loop CardVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful processing in the panel quickly and identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows for system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyMultiple panel networks can be programmed seamlessly as one system allowing for flexible design and system managementFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredIn the event of a fire or fault Vigilons analogue addressable technology will provide a detailed log of eventsExtended event log using flash memory cardPlease note This product requires either4 x 12v 24Ah Batteries NP24-12 or 8 x 12v 24Ah Batteries NP24-12.

GBP 3936.43
1

Gent VIGPLUS-72-NP Vigilon Plus 1-6 Loop Control Panel Without Printer with 1 Loop Card

Gent VIGPLUS-72-NP Vigilon Plus 1-6 Loop Control Panel Without Printer with 1 Loop Card

Gent VIGPLUS-72-NP Vigilon Plus 1-6 Loop Control Panel Without Printer with 1 Loop CardVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful processing in the panel quickly and identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows for system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyMultiple panel networks can be programmed seamlessly as one system allowing for flexible design and system managementFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredIn the event of a fire or fault Vigilons analogue addressable technology will provide a detailed log of eventsExtended event log using flash memory cardDoes not come with printerPlease note This product requires either4 x 12v 24Ah Batteries NP24-12 or 8 x 12v 24Ah Batteries NP24-12.

GBP 3580.97
1

Gent S4-34760 Duct Housing

Gent S4-34760 Duct Housing

Gent S4-34760 Duct HousingIncluding S-Quad Base and 0.6M TubeAn optical smoke sensor specifically designed for use in ventilation ducting. A venturi probe samples the air in the duct for smoke. Detector housing is mounted externally to the duct. This device can trigger the shut-down of an air-conditioning or ventilation plant to prevent the spread of smoke.Unfortunately air ducts do not just guarantee fresh air but in the event of a fi re they can also deliver toxic smoke from the fire source to distant area via the exhaust air system. Therefore air ducts must be monitored.The Gent duct sensor housing offers effective protection which is easy to install and maintain. The Gent duct sensor housing is supplied complete with an S Quad Sensor base and is thus compatible with the full range of S-Quad detectors S4-911 in high sensitivity state is recommended. The housing is mounted on the outside of the air duct. A Venturi pipe 0.6m 1.5m or 2.8m is inserted into the duct and delivers air from the duct through detection chamber and back to the duct. An air fl ow indicator shows whether there is an airflow through the housing.A maintenance hole in the transparent cover allows test spray to be applied without opening the cover. Using the Venturi effect means that a single sampling tube can be used and air velocities of as little as 1 Metre a second can be sensed. A mounting bracket is also available to mount the detector on circular and insulated ducts.The housing can be mounted in any orientation. The arrow shape design can be mounted in any orientation. The arrow shape design of the tough grey abs housing shows the direction of flow thus making installation quick and simple.Key FeaturesDirection of flow indicated by housingSingle sampling tubeCompatible with S-Quad SensorsSampling tubes available in three lengthsMounting bracket availableRemote LED can be installed via S-Quad monitor outputAir Duct uses Venturi processFully integrated into Vigilon loop

GBP 738.02
1

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop Card

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop Card

Gent COMPACT-PLUS Vigilon Compact Plus 1-2 Loop Control Panel with 1 Loop CardVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful software processing in the panel quickly identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredPlease note This product requires 2 x 12v 12Ah Batteries NP12-12.

GBP 1579.67
1

Gent VIGPLUS-24 Vigilon Plus 1-4 Loop Control Panel with 1 Loop Card

Gent VIGPLUS-24 Vigilon Plus 1-4 Loop Control Panel with 1 Loop Card

GentVIGPLUS-24Vigilon Plus 1-4 Loop Control Panel with 1 Loop CardVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful processing in the panel quickly and identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows for system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyMultiple panel networks can be programmed seamlessly as one system allowing for flexible design and system managementFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredIn the event of a fire or fault Vigilons analogue addressable technology will provide a detailed log of eventsExtended event log using flash memory cardPlease note This product requires2 x 12v 24Ah Batteries NP24-12.

GBP 2681.20
1

Gent NANO-24 Nano Control Panel

GBP 540.34
1

Gent 13270-02LB 2 Zone Conventional Xenex Fire Panel

Gent 13270-02LB 2 Zone Conventional Xenex Fire Panel

Gent 13270-02LB 2 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12.

GBP 256.49
1

Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel

Gent 13270-04LB 4 Zone Conventional Xenex Fire Panel

Gent 13270-04LB 4 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 2.1Ah Batteries NP2.1-12.

GBP 345.66
1

Gent 13270-08LB 8 Zone Conventional Xenex Fire Panel

Gent 13270-08LB 8 Zone Conventional Xenex Fire Panel

Gent 13270-08LB 8 Zone Conventional Xenex Fire PanelBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 3.2Ah Batteries NP3.2-12.

GBP 445.02
1

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less Batteries

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less Batteries

Gent 13271-08LB 8 Zone Xenex Conventional Fire Alarm Repeat Panel EN54 Less BatteriesBSI approved to EN54 Parts 2 4 the Xenex control panel can be used on installations meeting BS 5839Part1. Control panel options for 2-8 zones can be specified.Designed to simplify system installation each Xenex panel contains an integral power supply to drive up to 8 alarm sounder circuits 2 auxiliary relay contacts a zone disablement facility and also one-man test and commissioning features.Utilising LPCB approved conventional smoke or heat detectors Xenex offers exceptional value for money.Key FeaturesXenex deploys devices on conventional radial wiring layouts using standard 2-core cableDevice options include a full range of smoke detectors optical beam and duct types heat detectors fixed temperature or rate of rise types sounders strobes and bellsSounder options include shallow base deep base and bedhead sounder typesFor installations where a high degree of weatherproofing is required IP55 rated sounders sirens and bells are availableCommon accessories such as manual call points standard IP54 rated or key operated anti-vandal types available as either surface mounted or flush-fitted models door release units and Xenon flashers can all be accommodatedSpare test keys for testing manual call points without breaking the glass spare glasses packs of 10 and False alarm verification feature to filter out false alarms is selectable through softwarePlease note This product requires2 x 12v 3.2Ah Batteries NP3.2-12.

GBP 349.91
1

Gent VIGPLUS-24-NP Vigilon Plus 1-4 Loop Control Panel amp 1 Loop Card without Printer

Gent VIGPLUS-24-NP Vigilon Plus 1-4 Loop Control Panel amp 1 Loop Card without Printer

GentVIGPLUS-24-NP Vigilon Plus 1-4 Loop Control Panel 1 Loop Card without PrinterVigilon Plus Control Panels are available in 3 sizes managing 2 4 or 6 loops each accommodating up to 200 devices including advanced fire sensors interfaces call points alarm sounders and visual alarms. The Compact Plus 2 loop panels and Vigilon Plus 4 loop panels are available with integrated 24 hour standby and the 6-loop panel has full 72 hr standby capacity.Advanced networking options allow networking of up to 200 panels in a multi-domain structure with options of copper or optic fibre connections. Vigilons back-lit LCD display presents clear indication of Fire or Fault location and the control panels innovative 8-line x 40-character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilons software allows network areas to be sectored to evacuate or alert status or configured with pre-set delays.Fully compatible with Honeywell Gents innovative S-Quad range a combined Multi-Sensor range with speech sounder and EN54-23 Visual Alarm devices in one intelligent unit. The Vigilon Plus Repeat control panel provides full display and control of the system. Connecting to the detection loop the repeat panel provides a cost-effective solution with minimum requirements for cabling and installation. Repeat panels are supplied complete with their own 72-hour power supply.Key FeaturesVigilons advanced sensing technology and powerful processing in the panel quickly and identifies real firesPC based commissioning tools allow complex fire plans to be configuredAdvanced loop card technology allows for system status monitoring and diagnosticsThe control panel has a simple user interface with LCD screen providing accurate information in an emergencyMultiple panel networks can be programmed seamlessly as one system allowing for flexible design and system managementFlexible programming options are available at the panelAll Vigilon devices connect onto the same two core loop separate sounder or repeater panel wiring circuits are not requiredIn the event of a fire or fault Vigilons analogue addressable technology will provide a detailed log of eventsExtended event log using flash memory cardPlease Note This product requires 2 xYuasa 12V 24AH Battery Inverted Terminals NP24-12.

GBP 2431.50
1