16 results (0,14081 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Cooper Menvier EF-T107 2 x 70v Transformer Standard

Cooper Menvier EF-CMT 7 Inch Touchscreen Console with Gooseneck

Cooper MAB50R Addressable Reflective Beam Detector 50m Range

Cooper Bi-Wire Option Board 2 Relay BWOB2Z

Cooper Bi-Wire Option Board 8 Relay BWOB8Z

Cooper Bi-Wire Option Board 4 Relay BWOB4Z

Cooper Menvier EF-FMWB Fire Microphone - Wall Mounted

Cooper Menvier EFDAU500 Compact Wall Mounted Voice Alarm System

Cooper Menvier EFDAU500 Compact Wall Mounted Voice Alarm System

Cooper Menvier EFDAU500 Compact Wall Mounted Voice Alarm SystemThe networked voice alarm and public address system Compact DAU500 is based on the concept of a standalone or decentralised network topology with multi-channel amplifier and built-in local power backup. This state-of-the-art digital technology offers an audio distribution system which is a compact all-in-one wall-mounted solution where a flexible and easy to operate voice system installation.Compact DAU500 can be configured as a standalone or networked voice alarm system comprising of 6 loudspeaker circuits and consists of a central control unit with embedded amplifier cards 3 dual-channel amplifier cards EF-DA200 for 6 zones plus one dual-channel amplifier EF-DA200 for active back-up with integrated emergency power manager in accordance with EN54-4.Compact DAU500 is an optimised voice alarm andor public address system designed for small and medium sized applications. A standalone central control unit together with three EF-DA200 two channel amplifiers forms a complete voice alarm system for venues such as schools smaller hotels etc. The overall system achieves the performance requirements for voice alarm systems in accordance with EN54-16 and electro-acoustic emergency warning systems EN 50849.The Compact DAU500 central control unit has a built-in EN54-4 certified power supply equipment complete with 4 ampere intelligent charger and battery compartment.Each DAU500 panel supports memory storage for 22 pre-recorded messages of max. 5 minutes each they can be configured for alarm messages and signals evacuation alarm warning siren and attention signals siren chime. The volume of each source and each amplifier channel can be regulated using the 5-point parametric audio filter which is available for each input and output. Faults are recognized displayed and logged in compliance with standards within a few seconds.The Compact DAU500 central unit features 2 analogue balanced inputs for background music or an external analogue priority signal that can trigger an evacuation status.As standard the DAU500 panel is equipped with 6 independent amplifier channels which can operate a total of 6 loudspeaker circuits each loaded with a maximum of 100W. Amplifier channels can be bridged in pairs creating more powerful loudspeaker lines each capable of driving a 200W loudspeaker load. It is also possible to mix branch and loop line technology on the same central control unit. The number of loudspeaker circuits can be further expanded using the EF-HEXAPOD6 multiplexer units for phased evacuation applications the maximum number of loudspeaker circuits possible from a single DAU500 panel is 18 lines this limit can be extended further to 36 loudspeaker lines in non-phased evacuation applications.The Compact DAU500 directs two live stream audio channels and a serial data channel RS422 into remote zones via a redundant global network loop and controls a 6-channel message player that sends synchronized audio signals to the local zones. In this way each Compact DAU500 can play multiple audio messages simultaneously in the local zones. All announcement memory modules are synchronized between several Compact DAU500 panels supporting a wide area of warning message playback.Key FeaturesCompatible charger for 24 V DC backup batteries according to national standardsBattery backup storage for 24V battery from 10Ah to 55Ah2 x global network ports RJ45 for redundant ring monitored3 x local network ports RJ45 for local IO devices monitored2 x BGM one reserved for the fire station in the front panel8 x GPI terminal block opto-isolated8 x GPO terminal block open collectorSecured potential-free relay output EVAC FAULT RESETSecure input RESET SILENCE 6 x EVACLocal message player with storage of 22 audio files total length 110 minutesUSB interfacePre-programmed and exchangeable microSD cardControl and display board national language optionalFire station with access protection level 220kHz AC end-of-line monitoring with impedance deviation measurement EOLLoop line technology with LoopDrive 54-17 certified6x 100W or 3x 200W bridged continuous powerClass D 100V outputsOutput power at 230V mains voltage 6 x 100WOutput power with 24V DC emergency power supply 6 x 100WFrequency response 50Hz to 20KHz 3dBDistortion factor 0.1 at 1 kHz sineSignal to noise ratio 90dB A - weightedChannel separation 80dBEfficiency at maximum performance 80

GBP 8409.46
1

Cooper Menvier EF-FMTC Fire Microphone with Touchscreen and Gooseneck

Cooper Menvier EF-FMTC Fire Microphone with Touchscreen and Gooseneck

Cooper Menvier EF-FMTC Fire Microphone with Touchscreen and GooseneckThe desktopwall mounted microphone station EF-FMTC with touchscreen panel has been designed for use with the DAU500 voice alarm system. It can address up to 255 zones and trigger every source or message available in the entire system. It features gooseneck microphone for general paging and a separate fully monitored fireman microphone.The EF-FMTC desktop microphone offers dual mode operation paging mode firemans door closed where only general messages and paging features are available emergency mode firemans door open where emergency messages and firemans microphone is available.The microphone is connected to L-Net interface of DAU500 panel and may be daisy-chained with more L-Net devices. It is dedicated for call points where both general-purpose paging and emergency evacuation management is necessary. Fault monitoring and EVAC functionality are included making it suitable as an emergency microphone.Key FeaturesTable-top or wall mounted wall brackets includedHandheld firemens microphone with ALL-CALL buttonEquipped with EN54-16 mandatory indicatorsCoiled cord working length 1.10 mFully monitored fault systemAccess level protection by transparent coverAddressableRedundant L-Net link 2 x RJ452 x RJ45 for ring spur or daisy-chain interfacing with EFDAU500Configurable 7 touchscreen for paging control and status information30 cm gooseneck with dynamic hyper-cardioid microphone

GBP 1919.09
1

Cooper CF800PROG Intelligent Addressable Device Programmer

Cooper CDBB300 Conventional Detector Mounting Base EFXN520

Cooper CDBB300 Conventional Detector Mounting Base EFXN520

Cooper CDBB300 Conventional Detector Mounting Base EFXN520 Please note this will not work on the Legacy Menvier PanelsThe EFXN520 conventional standard base has been specifically designed to be compatible with the Cooper JSB range of conventional detectors. This standard base has been designed for flexibility simplicity and speed of installation.It incorporates purpose designed devices to provide fault warning if detector is removed whilst maintaining full zone wiring integrity. The base has a schotty diode in series with the negative terminals to enable fault monitoring and allow the circuit to continue if a detector is removed.Key FeaturesQuick and simple to installSeparate zone in and zone out terminalsStand-off fixing featureSelectable detector lockingBenefitsAccepts side entry surface cablesCommon base for JSB conventional detectorsInstallationBase incorporates a retaining clip to provide positive feedback when detector is correctly fitted.Separate terminals are provided for zone in and zone out connections.Each terminal can accept up to 2 x 2.5mm cablesBase incorporates a substantial cable entry aperture in the rear of the base.Breakouts are provided to enable the detector base to sit neatly over surface cables and then enter via the rear entry aperture.Base mounting incorporates a stand-off feature to help prevent distortion when mounted on anuneven surface.Fixings are suitable for standard BESA box or direct fixing to suitable surfaceOptional locking devices supplied with base to prevent unauthorised detector removal.

GBP 4.02
1

Cooper Menvier DAX8 Digital Analogue Exchange 8 Line

Cooper Menvier DAX8 Digital Analogue Exchange 8 Line

Cooper Menvier DAX8 Digital Analogue Exchange 8 LineDAX8 is a loop powered digital to analogue convertorused in conjunction with VoCALL 16 to ensure simplicityof future legacy system upgrade or expansion.This loop powered convertor allows the connectionof existing analogue outstations to a digital system. Amaximum of 8 analogue outstations of any combinationcan be connected to the DAX8 with a maximum of twoDAX8 units per panel. The loop wired connection to theDAX8 along with short circuit insulators ensures thenetwork is robust and fault tolerant.Compatible analogue outstations include the type Atype B Jack point and emergency assist alarm EAA.Utilising a minimum of one MX panel and up to 31additional lower cost NX network panels the DAX8enables system takeovers of up to 512 analogueoutstations utilising existing Eaton loop and radial cableconfigurations.The simplicity of operation ease of cabling andcompetitive pricing makes the system suitable for awide range of applications. The DAX8 can be wiredin combination with our range of soft addressabledigital outstations ensuring the maximum fl exibility intakeovers upgrades and expansion of EVC systems.The DAX8 also ensures compatibility with our low-costjack point for regions where this system is allowed bybuilding code allowing up-to 512 individually addressedjack points per system or 512 lines of jack points withpotentially over 10240 points available.Key FeaturesUp to 64 DAX8 units within a networkUp to 8 analogue outstations per DAX84 core loop connection to host panel8 x 2 core radial spurs for legacy analogue outstationsUpgrade existing systems to a digital isolated networkRequires at-least 1 MX panel per systemAny other combination of panels MXNX possibleAny combination of analogue outstations possible.Easy to install and commissionSoft addressed panel digital outstation and DAX8Embedded Webserver application for configurationLoop isolators built into the DAX8Built in end of line monitoring of legacy outstationsDill switch identification for legacy outstationsUses existing CFVCX8 footprintEmergency assist toilet alarms are powered from the DAX8Fully compliant with BS5839-9Network capacity of 512 outstations

GBP 609.11
1