16 results (0,14604 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Cooper Bi-Wire Option Board 2 Relay BWOB2Z

Cooper Bi-Wire Option Board 8 Relay BWOB8Z

Cooper Bi-Wire Option Board 4 Relay BWOB4Z

Cooper MCIM Micro Single Channel Input Unit recognised as a input unit

Cooper CAH330 Intelligent Addressable Multi-Mode Heat Sensor MAH830 FXN725 400003FIRE-0003X

Cooper MCOM-S Micro Single Channel Output Unit recognised as a sounder

Cooper MCOM Micro Single Channel Output Unit recognised as a output unit

Cooper MCOM-R Micro Single Channel Output Unit 5 second reset pulse

Cooper CIOP-7273 Addressable Door Release Module

Cooper MAB50R Addressable Reflective Beam Detector 50m Range

Cooper LP800KIT Loop Tester Kit

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode Heat Sensor

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode Heat Sensor

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode HeatSensorThis range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensation

GBP 34.94
1

Cooper CIOP4 4 Way Mimic Relay Board with 4 Inputs amp 4 Outputs

Cooper CIOP4 4 Way Mimic Relay Board with 4 Inputs amp 4 Outputs

Cooper CIOP4 4 Way Mimic Relay Board with 4 Inputs 4 OutputsThese addressable mimic relay boards CIOP4 and CIOP8 are 4 and 8 way soft addressing output modules incorporating integral short circuit isolators.Both the CIOP4 and the CIOP8 mimic relay boards are fully compatible with the current range of Cooper intelligent addressable control panels. The units are suitable for switching low voltage 24V dc at 1A maximum via a set of non-latching relay contacts.The flexibility of these modules is further enhanced by the fact that each output can be programmed for a range of triggers such as disablement fault fire test panel test zone pre-alarm fire routing equipment fire protecting equipment and reset with up to 16 different trigger sources per output.The trigger source can be global by panel by loop by zone or by address. The logic is available in both OR AND functions.These units have an additional 4 inputs which can initiate a reset silence evacuate and test function.They can be programmed using the CF3000 programmable site installer software and downloaded using the RS232 port.Key FeaturesLoop poweredUnits can be soft or hard addressedIntegral short circuit isolatorSingle address4 input 4 output version4 input 8 output versionPCB version incorporates 4 inputs- Reset- Silence- Evacuate- Test16 settings per outputTrigger types fire fault disablement test prealarm FRE FPE resetTrigger source global by panel by loop by zone by addressLogic functions OR ANDBenefitsQuick and simple to installPluggable terminals for ease of wiringProgrammable via site installer softwareCost effective installation solution

GBP 372.41
1

Cooper CIOP8 8 Way Mimic Relay Board with 4 Inputs amp 8 Outputs

Cooper CIOP8 8 Way Mimic Relay Board with 4 Inputs amp 8 Outputs

Cooper CIOP8 8 Way Mimic Relay Board with 4 Inputs 8 OutputsThese addressable mimic relay boards CIOP4 and CIOP8 are 4 and 8 way soft addressing output modules incorporating integral short circuit isolators.Both the CIOP4 and the CIOP8 mimic relay boards are fully compatible with the current range of Cooper intelligent addressable control panels. The units are suitable for switching low voltage 24V dc at 1A maximum via a set of non-latching relay contacts.The flexibility of these modules is further enhanced by the fact that each output can be programmed for a range of triggers such as disablement fault fire test panel test zone pre-alarm fire routing equipment fire protecting equipment and reset with up to 16 different trigger sources per output.The trigger source can be global by panel by loop by zone or by address. The logic is available in both OR AND functions.These units have an additional 4 inputs which can initiate a reset silence evacuate and test function.They can be programmed using the CF3000 programmable site installer software and downloaded using the RS232 port.Key FeaturesLoop poweredUnits can be soft or hard addressedIntegral short circuit isolatorSingle address4 input 4 output version4 input 8 output versionPCB version incorporates 4 inputs- Reset- Silence- Evacuate- Test16 settings per outputTrigger types fire fault disablement test prealarm FRE FPE resetTrigger source global by panel by loop by zone by addressLogic functions OR ANDBenefitsQuick and simple to installPluggable terminals for ease of wiringProgrammable via site installer softwareCost effective installation solution

GBP 380.40
1

Cooper Menvier 400002FIRE-0002X Addressable Optical Smoke Sensor

Cooper Menvier 400002FIRE-0002X Addressable Optical Smoke Sensor

Cooper Menvier 400002FIRE-0002X Addressable Optical SmokeSensorThis range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensationAesthetically pleasingQuick and simple to installSingle multi-mode heat sensorWide viewing angle for increased LED visibilityCommon mounting basePositive lock indicationDiscreet design for incorporation into any dcorEasy to maintainservice

GBP 34.98
1

Cooper Menvier 400004FIRE-0004X Addressable Photo-Thermal Sensor

Cooper Menvier 400004FIRE-0004X Addressable Photo-Thermal Sensor

Cooper Menvier 400004FIRE-0004X Addressable Photo-ThermalSensor This range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensationAesthetically pleasingQuick and simple to installSingle multi-mode heat sensorWide viewing angle for increased LED visibilityCommon mounting basePositive lock indicationDiscreet design for incorporation into any dcorEasy to maintainservice

GBP 42.90
1