32 results (0,15892 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec PDA200E Wall Mounting Hearing Loop Amplifier 200m2

C-Tec PDA200E AKW1 Hearing Loop Kit for Place of Worship with Fixed Lectern Microphone

C-Tec PDA200E AKW1 Hearing Loop Kit for Place of Worship with Fixed Lectern Microphone

C-Tec PDA200E AKW1 Hearing Loop Kit for Place of Worship with Fixed Lectern MicrophoneHearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearingloop amplifier AML lectern microphone APJ 3.5mm jack input plate APL line level audio inputplate and 2 x 6m of Belden cable. Ideal for creatinga high-quality hearingloop system for a place of worship.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 452.76
1

C-Tec PL1K1 Portable Hearing Loop Kit with Storage Shelf 1.2m2

C-Tec PL1K1 Portable Hearing Loop Kit with Storage Shelf 1.2m2

C-Tec PL1K1 Portable Hearing Loop Kit with Storage Shelf 1.2m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.The PL1K1 is ideal for restricted person to person contact in areas such as banks post offices small meeting rooms reception desks open plan offices and ticket booths. The units portable lightweight design means the system can be moved easily from location to location.Key FeaturesSimple one button operation.Integral high-performance microphone.Excellent sound quality.Five years expected battery life under normal operatingcharging conditions.Auto shut-off facility user selectable for 10 30 or 60 minutes helps preserve battery life.Connection of the plug-top charger overrides the timer function to ensure the unit remains operational at all times.Unit can be used as normal whilst charging.Technical SpecificationType - PortableCoverage - 1.2m2 approx.Dimensions - W 271 x H 200 x D 77mm amplifier only 2.82kgInputs 2 x Mic one built-in mic. and one 3.5mm remote mic. socket for AMT or AMD micsIndicators - Power on input level charging required charging in progress audio warning of imminent shutdownControls - Onoff button adjust auto-shut off timer

GBP 202.64
1

C-Tec PDA200E AKR1 Hearing Loop Kit for Waiting Rooms 200m2

C-Tec PDA200E AKR1 Hearing Loop Kit for Waiting Rooms 200m2

C-Tec PDA200E AKR1 Hearing Loop Kit for Waiting Rooms 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearingloop amplifier and APL line level audio inputplate for connecting to a paging system and 6m of Belden cable. Ideal for creatinga high quality hearingloop system for a waiting room.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 304.80
1

C-Tec PDA200E AKL1 Hearing Loop Kit for Lecture Rooms 200m2

C-Tec PDA200E AKL1 Hearing Loop Kit for Lecture Rooms 200m2

C-Tec PDA200E AKL1 Hearing Loop Kit for Lecture Rooms 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearingloop amplifier AMT tiedesk microphone AML lectern microphone 2 x APJ 3.5mm jack input plates 2 x 6m Belden cable. Ideal for creatinga high-quality induction loop system for a Lecture room.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop driveAKL1 Meeting room kit PDA200E amplifier AMT tiedesk mic. AML lectern mic. 2 x APJ outreach plates AFILS fitted sticker.Please Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 422.02
1

C-Tec PL1K3 Portable Hearing Loop Kit with Carry Case 1.2m2

C-Tec PL1K3 Portable Hearing Loop Kit with Carry Case 1.2m2

C-Tec PL1K3 Portable Hearing Loop Kit with Carry Case 1.2m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.The PL1K3 is ideal for restricted person to person contact in areas such as banks post offices small meeting rooms reception desks open plan offices and ticket booths. The unit is supplied in arobustplastic storage case.Key FeaturesPortable lightweight design.Simple one button operation.Integral high-performance microphone.Excellent sound quality.Five years expected battery life under normal operatingcharging conditions.Auto shut-off facility user selectable for 10 30 or 60 minutes helps preserve battery life.Connection of the plug-top charger overrides the timer function to ensure the unit remains operational at all times.Unit can be used as normal whilst charging.Note this version of our portable loop amplifier does not include a wall-mounting storage shelf.Technical InformationType - PortableCoverage - 1.2m2 approx.Dimensions - W 271 x H 200 x D 77mm amplifier only 2.82kgInputs 2 x Mic one built-in mic. and one 3.5mm remote mic. socket for AMT or AMD micsIndicators - Power on input level charging required charging in progress audio warning of imminent shutdownControls - Onoff button adjust auto-shut off timer

GBP 345.96
1

C-Tec PDA200E AKW2H Hearing Loop Kit for Place of Worship with Handheld Radio Microphone 200m2

C-Tec PDA200E AKW2H Hearing Loop Kit for Place of Worship with Handheld Radio Microphone 200m2

C-Tec PDA200E AKW2H Hearing Loop Kit for Place of Worship with Handheld Radio Microphone 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearing loop amplifierAMRHA handheld radio microphone APJ outreach plate APXMoutreach plate for use with existing mics and 2 x 6m of Belden cable. Ideal for creatinga high-quality hearingloop system for aTV or Music lounge.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.AMRHA handheld radio microphone kit includes receiver transmitter PSU and 4 selectable frequencies.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 992.46
1

C-Tec PDA200E AKW2L Hearing Loop Kit for Place of Worship with Levalier Radio Microphone 200m2

C-Tec PDA200E AKW2L Hearing Loop Kit for Place of Worship with Levalier Radio Microphone 200m2

C-Tec PDA200E AKW2L Hearing Loop Kit for Place of Worship with Levalier Radio Microphone 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearing loop amplifier AMRLA lavalier radio microphone APJ outreach plateAPXM outreach plate for use with existing mics and 2 x 6m Belden cable. Ideal for creatinga high-quality hearingloop system for a place of worship.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.AMRLA lavalier radio microphone kit includes receiver transmitter PSU and 4 selectable frequencies.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 992.46
1

C-Tec PDA200E AKM1 Hearing Loop Kit for Meeting Seminar Room 200m2

C-Tec PDA200E AKM1 Hearing Loop Kit for Meeting Seminar Room 200m2

C-Tec PDA200E AKM1 Hearing Loop Kit for Meeting Seminar Room 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearingloop amplifier APM omni-directional plated microphone and 6m of Belden cable. Ideal for creatinga high-quality hearingloop system for a meeting or seminar room. Wall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Key FeaturesInternal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.APM microphone provides up to25m2 ambient coverage or 2.5m2 direct speechcoverage from aceiling height of 2.5 to 3m.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop driveAKM1 Meeting room kit PDA200E amplifier APM plated mic. AFILS fitted stickerPlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 315.88
1

C-Tec PDA200E AKH1L Hearing Loop Kit for Health and Fitness Club 200m2

C-Tec PDA200E AKH1L Hearing Loop Kit for Health and Fitness Club 200m2

C-Tec PDA200E AKH1L Hearing Loop Kit for Health and Fitness Club 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearing loop amplifierAMRLA lavalier radio microphone APJ outreach plate APLoutreach plate audio input for CDtape deck and 2 x 6m Belden cable. Ideal for creatinga high-quality hearingloop system for a health and fitness club.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.AMRLA lavalier radio microphone kit includes receiver transmitter PSU and 4 selectable frequencies.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 1022.15
1

C-Tec PDA200E AKT1 Hearing Loop Kit for TV Music Lounge 200m2

C-Tec PDA200E AKT1 Hearing Loop Kit for TV Music Lounge 200m2

C-Tec PDA200E AKT1 Hearing Loop Kit for TV Music Lounge 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearingloop amplifier AMP handheld microphone APS SCART to double phono lead APXM outreach plate APL outreach plate AL5 lead and 2 x 6m Belden cable. Ideal for creatinga high-quality induction loop system for aTV or Music lounge.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.Loop cable not included-use our LOOP2W1mm2 cable or download our AFILS loop calculator from our Software Apps page formore precise recommendations.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 843.79
1

C-Tec PDA200E AKM3 Hearing Loop Kit for Professional Meeting Seminar Room 200m2

C-Tec PDA200E AKM3 Hearing Loop Kit for Professional Meeting Seminar Room 200m2

C-Tec PDA200E AKM3 Hearing Loop Kit for Professional Meeting Seminar Room 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearing loop amplifier PRO45 hanging ambient microphone APXM outreach plate and 6m Belden cable. Ideal for creatinga high-quality induction loop system for a professional meeting or seminar room.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop driveAKM3 Meeting room kit PDA200E 200m2 hearing loop amplifier PRO45 hanging ambient microphone APXM XLR mic. Level connector plate 1 x 6m Belden cable Loop Fitted sticker. Loop cable is not included.Please Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 834.25
1

C-Tec ZFP Standard 2 Loop Touchscreen Panel with 40 Zonal LEDs

C-Tec ZFP Standard 2 Loop Touchscreen Panel with 40 Zonal LEDs

C-Tec ZFP Standard 2 Loop Touchscreen Panel with 40 Zonal LEDsCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Attractive 450 x 462 x 127mm cabinet medium and large sized cabinets also available.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and singlepath networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 1626.25
1

C-Tec ZFP Standard 1 Loop Touchscreen Panel with 40 Zonal LEDs

C-Tec ZFP Standard 1 Loop Touchscreen Panel with 40 Zonal LEDs

C-Tec ZFP Standard 1 Loop Touchscreen Panel with 40 Zonal LEDsCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Attractive 450 x 462 x 127mm cabinet medium and large sized cabinets also available.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and single path networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless-steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 1217.53
1

C-Tec ZFP Standard 1 Loop Touchscreen Panel with Blank Module

C-Tec ZFP Standard 1 Loop Touchscreen Panel with Blank Module

C-Tec ZFP Standard 1 Loop Touchscreen Panel with Blank ModuleCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Attractive 450 x 462 x 127mm cabinet medium and large sized cabinets also available.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and single path networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless-steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 1049.62
1

C-Tec ZFP2MX Medium 2 Loop Touchscreen Panel with 3 Blank Modules

C-Tec ZFP2MX Medium 2 Loop Touchscreen Panel with 3 Blank Modules

C-Tec ZFP Medium 2 Loop Touchscreen Panel with 3 Blank ModulesCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Attractive 450 x 462 x 127mm cabinet medium and large sized cabinets also available.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and singlepath networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 1777.44
1

C-Tec ZFP2X Standard 2 Loop Touchscreen Panel with Blank Module

C-Tec ZFP2X Standard 2 Loop Touchscreen Panel with Blank Module

C-Tec ZFP Standard 2 Loop Touchscreen Panel with Blank ModuleCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Attractive 450 x 462 x 127mm cabinet medium and large sized cabinets also available.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and singlepath networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 1458.20
1

C-Tec ZFP Medium 8 Loop Touchscreen Panel with 3 Blank Modules

C-Tec ZFP Medium 8 Loop Touchscreen Panel with 3 Blank Modules

C-Tec ZFP Medium 8 Loop Touchscreen Panel with 3 Blank ModulesCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and single path networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless-steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 3312.91
1

C-Tec ZFP8LX ZFP Large 8 Loop Touchscreen Panel with 5 Blank Modules

C-Tec ZFP8LX ZFP Large 8 Loop Touchscreen Panel with 5 Blank Modules

C-TecZFP8LX ZFP Large 8 Loop Touchscreen Panel with 5 Blank ModulesCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and single path networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless-steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 3440.59
1

C-Tec ZFP2LX ZFP Large 2 Loop Touchscreen Panel with 5 Blank Modules

C-Tec ZFP2LX ZFP Large 2 Loop Touchscreen Panel with 5 Blank Modules

C-TecZFP2LXZFP Large 2 Loop Touchscreen Panel with 5 Blank ModulesCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Attractive 450 x 462 x 127mm cabinet medium and large sized cabinets also available.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and singlepath networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 1905.13
1

C-Tec ZFP Standard 2 Loop Touchscreen Panel with 20 Zonal LEDs Printer amp Key Switches

C-Tec ZFP Standard 2 Loop Touchscreen Panel with 20 Zonal LEDs Printer amp Key Switches

C-Tec ZFP Standard 2 Loop Touchscreen Panel with 20 Zonal LEDs Printer Key SwitchesCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Attractive 450 x 462 x 127mm cabinet medium and large sized cabinets also available.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and singlepath networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 1910.42
1

C-Tec ZFP4MX Medium 4 Loop Touchscreen Panel with 3 Blank Modules

C-Tec ZFP4MX Medium 4 Loop Touchscreen Panel with 3 Blank Modules

C-Tec ZFP Medium 4 Loop Touchscreen Panel with 3 Blank ModulesCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Attractive 450 x 462 x 127mm cabinet medium and large sized cabinets also available.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and singlepath networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 2186.05
1

C-Tec ZFP Standard 2 Loop Touchscreen Panel with 20 Zonal LEDs

C-Tec ZFP Standard 2 Loop Touchscreen Panel with 20 Zonal LEDs

C-Tec ZFP Standard 2 Loop Touchscreen Panel with 20 Zonal LEDsCreated with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesCertified to EN54 parts 2 and 4 by Intertek.Apollo XP95Discovery protocol.Attractive 450 x 462 x 127mm cabinet medium and large sized cabinets also available.Up to 4 loops per panel 6 to 8 loops available in medium and large sized cabinets.Up to 64 eight-loop peer to peer panel network capacity.Hi-integrity and singlepath networking options.Very flexible cause and effects.Wide range of Switch Indicator modules.Multiple A-Bus expansion PCBs IO Units Relays etc.User-friendly full colour touchscreen with dynamic buttons and virtual QWERTY keyboard.Up to 100 separate and programmable zonal LEDs 200 on medium and large sized cabinets.10000 programmable and indicatable detection zones.Up to 38 characters of custom text per loop device.Automatic daylight saving BSTGMT mode.20000 event memory filterable by fire fault date.Non-fire supervisory event functionality.Optional thermal printers.Well-designed cabinets with easily removable electronics chassis.20-way heavy-duty brass earth bar as standard.72-hour standby 30 min alarm in standard cabinets.Built-in loop status current-reading.Powerful engineering and commissioning functions including SafeMode and DeviceManager.Attractive Compact Controllers.Wide range of flush-fit bezels and attractive glazed stainless steel framesFULLY compatible with C-TEC manufactured addressable ancillaries Hush Buttons Sounders Voice Sounders and BeaconsPowerful and intuitive PC programming toolsWide range of supported languages

GBP 1585.91
1