20 results (0,13440 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Baldwin Boxall Relay 5A 8 Way PCB B81R

Baldwin Boxall BVCRM3 Rack Mount Kit for Mini Consoles 8-32 Way 7U

Baldwin Boxall Q1233M 8-way Button Card For Omnicare Control Panels

Baldwin Boxall BT8EX BT8 8 Zone Dial-up Interface - 110V

Baldwin Boxall 8 Zone Intelligent Paging Microphone BDM408

Baldwin Boxall 8 Zone Intelligent Paging Microphone BDM408

Baldwin Boxall 8 Zone Intelligent Paging Microphone BDM408BDM400 microphones for public address and voice alarm systems. The BDM400 range of intelligent paging microphones is designed to provide a wide variety of features to suit any installation. There are six microphones available in the range one-zone to 32-zone.Key FeaturesAvailable in six versions - from one-zone up to 32-zone.Communicate with the main control system via an RS485 link.A standard RJ45 CAT5 network cable is used to carry both audio and serial data.Microphones can be linked together via wall sockets - product code BMS8 and connected to a single input at the control rack.The BDM401 can also be operated as a parallel microphone. This option is selected internally by jumpers. Factory setting is for serial operation.Ergonomic design with all buttons and indicators mounted behind a stylish overlay that allows zone button labels to be inserted and protected.The dynamic cardoid microphone capsule can be set for either monitored or unmonitored use during configuration.Zone status indicators show if a zone is currently selected or in use.All call paging except BDM401.Speak now indicator to show the user when a pre-announcement chime has finished.Simple bar graph display shows the user the current speech volume ensuring a clear announcement is made.Data and DC indicators to show the unit is functioning correctly.Zonal fault indicators are included to show when a fault is evident on the system.Fault accept button.Option to fit flip-top switches to enable DVA digital voice announcement messages to be broadcast.

GBP 635.04
1

Baldwin Boxall 8 Zone Paging Telephone Interface BT8

Baldwin Boxall 8 Zone Paging Telephone Interface BT8

Baldwin Boxall 8 Zone Paging Telephone Interface BT8Our telephone interface units enable staff to make public address announcements from their own desk telephone. The free-standing units act as an interface between the analogue telephone system and the amplifier.Key FeaturesOperated by simply dialling the BT5BT8 extension number.Each unit is supplied with an IEC mains lead.Can be used to broadcast live announcements.Additional facility enables the user to pre-record an announcement. This reduces the risk of feedback where the telephone is adjacent to a loudspeaker.When connected to a telephone system with MF signalling the BT8 enables the user to select up to eight zones via the telephone keypad.An internal selector determines if the recorded message is played once or twice.Can be wired into any two-wire analogue extension port via a designated master extension socket. Another option is to connect the unit to the paging port available on most modern telephone switches. However they are not designed to operate on keyphone system extension ports.Outputs are selectable from line or microphone level.Signal output and zone select connections are via a 25 way D connector.Compatible with our BDM300 range of desk microphones connected via the BMS25 socket box supplied with the microphone.We recommend using our B81R relay unit for the zone select switching.Please note the BT8 is not approved for direct connection to the BT network. Under general approval NSG23J100003 it may be connected to a port on a telephone switch PABX. This unit should only be used with a switchable amplifier input.

GBP 1050.54
1

Baldwin Boxall Q1332 Termination Board For Omnicare 8-32 Way Control Panel

Baldwin Boxall BVOC8M72 Omnicare Console 8-Way - 72Hrs

Baldwin Boxall BVOC8M72 Omnicare Console 8-Way - 72Hrs

Baldwin Boxall BVOC8M72 Omnicare Console 8-Way - 72HrsOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.Batteries not included.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 1993.12
1

Baldwin Boxall VIGIL2 Slave Router BVRD2SLT adds 6 Inputs 8 Outputs and 6 Messages

Baldwin Boxall Omnicare Mini EVC Control Panel 8-way BVOC8M

Baldwin Boxall Omnicare Mini EVC Control Panel 8-way BVOC8M

Baldwin Boxall Omnicare Mini EVC Control Panel 8-way BVOC8MOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration.

GBP 1729.13
1

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-Way

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-Way

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 6586.27
1

Baldwin Boxall VIGIL2 EVAS Router with 8 Inputs and 7 Audio Outputs BVRD2M

Baldwin Boxall VIGIL2 EVAS Router with 8 Inputs and 7 Audio Outputs BVRD2M

Baldwin Boxall VIGIL2 EVAS Router with 8 Inputs and 7 Audio Outputs BVRD2MThe VIGIL EVAS BVRD2M DSP-controlled router is well-established and has been installed in many prestigious sites Worldwide.VIGIL EVAS routers are feature rich and in common with all Baldwin Boxall products are built to a very high standard. A voice alarm system MUST work when needed during an emergency such as a fire. Baldwin Boxalls voice alarm systems are renowned for their reliability and can be installed with confidence.There are two routers in the EVAS range the BVRD2M and the BVRD2M4 as well as slave router options. The modular style of the VIGIL2 voice alarm system offers great choice and flexibility. It is as suitable for small systems as it is for very large networked systems.Key FeaturesDSP control.Eight electronically balanced inputs. Inputs one and two are configurable with all call processor bypass and are normally reserved for fire microphones. All inputs have both independent priority and level settings.Up to fifteen priority levels are available. If two concurrent routes are set at the same priority they will be treated on a first come first served basis. Priorities are changeable.Three band parametric plus bass and treble equalisation on all inputs with limitercompressor enhancing the intelligibility of the system.All call failsafe emergency message generator twenty second EPROM.Seven electronically balanced audio outputs with ten band parametric equalisation and audio delay of up to one second.Fully monitored surveillance at either 30Hz or 20kHz faults are recorded in the history log. All inputs outputs and DSP messages can be aurally monitored through a loudspeaker on the front panel.Built-in real-time clock enables detailed logging and reporting including detected faults. Indicates time date month and year. Also used for night time volume reduction timed message trigger and to control external inputs. The history log can be accessed via the USB2 port on the front panel.Six flash stored 57 second messages with independent level surveillance and timing. For longer non-critical messages up to three can be combined. Settings and messages are changeable password protected via the USB2 port.Nine selectable chimes pre-announcement tones of up to eight seconds in length.Expandable with BVRD2S slave router and CANBUS modules.Up to 126 EVAS routers can be networked using fibre or copper to produce a truly sophisticated digital VA network.Message synchronisation even on a decentralised system.Ambient noise sensing.Amplifier changeover one in ten.Two RS485 ports for networking microphones etc.Zone grouping and barring on BVRD voice alarm controller.

GBP 4187.64
1

Baldwin Boxall Impedance Monitor BVLAM

Baldwin Boxall Impedance Monitor BVLAM

Baldwin Boxall Impedance Monitor BVLAMThe BVLAM provides 8 zone 100V line relay switching loudspeaker zone selection from 1 amplifier.It incorporates impedance monitoring on all 8 loudspeaker lines when the zone is not selected. If the load increases impedance decreases the appropriate fault LED illuminates steady and if the load decreases impedance increases the fault LED will flash.The impedance changes for a fault to be detected is selected to either 20 or 40 using the mode DIL switch 8. If the impedance falls to approximately 50 of its original value the line is considered to be short circuit and will not be selected to the amplifier.All 8 zone select inputs will access when it is between 2 to 6.5V. An open circuit access input above 15V will be indicated by the appropriate fault LED flashing and a short circuit access input below 2V by the fault LED illuminating steady.Under all fault conditions the OK LED will extinguish and the common fault relay volt-free contacts to change state.Key FeaturesRack-mountable unit 1U high. Two units can be mounted across one rack shelf.Provides eight loudspeaker zone selection from one amplifier.On receipt of a signal from an input ie zone selecting microphone the BVLAM triggers the amplifier to output to the selected zone.An internal relay enables zone switching.The BVLAM provides constant impedance monitoring on each of the eight loudspeaker circuits when not selected.LEDs are used to indicate a drop or increase in impedance - set at either 20 or 40 by DIL switches.Note due to detection accuracy BVLAM is only suitable for BS5839-8 voice alarm systems with less than five speakers per circuit.Access faults on any of the zones from the microphone are indicated by LEDs on the BVLAM.Additional LED indicators are provided to show system healthy and supply healthy.The Baldwin Boxall Impedance Monitor BVLAM provides a combination of zones relay switches from one amplifier. It changes if a fault is detected.

GBP 880.90
1

Baldwin Boxall CARE2 Network Expansion Panel 4-way C2CBNEP

Baldwin Boxall Care2 EVC Network Expansion Panel C2CSNEP

Baldwin Boxall Control Interface for Universal Zonal Access Switching BVRDCI