198 results (0,14581 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Baldwin Boxall CARE2 Omnicare Remote Lamp and Buzzer BVOCCA

Baldwin Boxall VIGIL2 EVAS Router with 8 Inputs and 7 Audio Outputs BVRD2M

Baldwin Boxall VIGIL2 EVAS Router with 8 Inputs and 7 Audio Outputs BVRD2M

Baldwin Boxall VIGIL2 EVAS Router with 8 Inputs and 7 Audio Outputs BVRD2MThe VIGIL EVAS BVRD2M DSP-controlled router is well-established and has been installed in many prestigious sites Worldwide.VIGIL EVAS routers are feature rich and in common with all Baldwin Boxall products are built to a very high standard. A voice alarm system MUST work when needed during an emergency such as a fire. Baldwin Boxalls voice alarm systems are renowned for their reliability and can be installed with confidence.There are two routers in the EVAS range the BVRD2M and the BVRD2M4 as well as slave router options. The modular style of the VIGIL2 voice alarm system offers great choice and flexibility. It is as suitable for small systems as it is for very large networked systems.Key FeaturesDSP control.Eight electronically balanced inputs. Inputs one and two are configurable with all call processor bypass and are normally reserved for fire microphones. All inputs have both independent priority and level settings.Up to fifteen priority levels are available. If two concurrent routes are set at the same priority they will be treated on a first come first served basis. Priorities are changeable.Three band parametric plus bass and treble equalisation on all inputs with limitercompressor enhancing the intelligibility of the system.All call failsafe emergency message generator twenty second EPROM.Seven electronically balanced audio outputs with ten band parametric equalisation and audio delay of up to one second.Fully monitored surveillance at either 30Hz or 20kHz faults are recorded in the history log. All inputs outputs and DSP messages can be aurally monitored through a loudspeaker on the front panel.Built-in real-time clock enables detailed logging and reporting including detected faults. Indicates time date month and year. Also used for night time volume reduction timed message trigger and to control external inputs. The history log can be accessed via the USB2 port on the front panel.Six flash stored 57 second messages with independent level surveillance and timing. For longer non-critical messages up to three can be combined. Settings and messages are changeable password protected via the USB2 port.Nine selectable chimes pre-announcement tones of up to eight seconds in length.Expandable with BVRD2S slave router and CANBUS modules.Up to 126 EVAS routers can be networked using fibre or copper to produce a truly sophisticated digital VA network.Message synchronisation even on a decentralised system.Ambient noise sensing.Amplifier changeover one in ten.Two RS485 ports for networking microphones etc.Zone grouping and barring on BVRD voice alarm controller.

GBP 4187.64
1

Baldwin Boxall VIGIL2 EVAS Router with 4 Inputs and 4 Audio Outputs BVRD2M4

Baldwin Boxall VIGIL2 EVAS Router with 4 Inputs and 4 Audio Outputs BVRD2M4

Baldwin Boxall VIGIL2 EVAS Router with 4 Inputs and 4 Audio Outputs BVRD2M4The BVRD2M4 is a four-zone voice alarm router with the same great features as the BVRD2M designed for smaller installations and networked decentralised systems.Key FeaturesDSP control.Possible to monitor up to four dual AB circuits.Four electronically balanced inputs. Input one is configurable with all call processor bypass and is normally used for the fire microphone in voice alarm systems. All inputs have both independent priority and level settings allowing for dual mode emergency and normal page.Up to fifteen priority levels are available. If two concurrent routes are set at the same priority they will be treated on a first come first served basis. Priorities are changeable.Three band parametric plus bass and treble equalisation on all inputs with limitercompressor enhancing the intelligibility of the system.Four audio electronically balanced 0dBM outputs with ten band parametric equalisation and audio delay of up to one second.Fully monitored surveillance at either 30Hz or 20kHz faults are recorded in the history log.Built-in real-time clock enables detailed logging and reporting including detected faults. Indicates time date month and year. Also used for night time volume reduction timed message trigger and to control external inputs. The history log can be accessed via the USB2 port on the front panel.Six flash stored 57 second messages with independent level surveillance and timing. Settings and messages are changeable password protected via the USB2 port.Nine selectable chimes pre-announcement tones of up to eight seconds in length.Up to 126 EVAS routers can be networked using fibre or copper to produce a truly sophisticated VA network.Message synchronisation even on a decentralised system.Ambient noise sensing using optional ambient noise sensing microphones.Amplifier changeover for up to three zones using optional relay board product code BVRD2M4ACO.Two RS485 ports for networking microphones etc.Zone grouping and barring on BVRD voice alarm controller.

GBP 1813.49
1

Baldwin Boxall Omnicare Combined Red Fire Telephone and Green DRS Unit BVOCCGCP

Baldwin Boxall VIGIL2 Slave Router BVRD2S adds 12 Inputs 16 Outputs and 12 Messages

Baldwin Boxall VIGIL2 Slave Router BVRD2SLT adds 6 Inputs 8 Outputs and 6 Messages

Baldwin Boxall OmniCarePLUS Control Hub with Touch Screen PC and Monitor Mounted Phone BVOCTSPCM

Baldwin Boxall DTASCBRP Care2 Call Button amp Reset Point Stainless Steel

Baldwin Boxall Care2 EVC Network Expansion Panel C2CSNEP

Baldwin Boxall CARE2 Network Expansion Panel 4-way C2CBNEP

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4Care2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall. It is stylish versatile and easy to use and offers an alternative to our well-established loop-wired Omnicare range.Key FeaturesCARE2 is an all-in-one Emergency Voice Communication EVC system.Fully monitored and battery-backed 24 hours quiescent and three hours functional.Fully compliant to BS5839-92011. Assists companies with compliance to BS99992008.Remote units are wired in a radial star configuration using two core fire resisting enhancednon-enhanced cable.Fully networkable. Networked panels are wired in a loop configuration using 2 x two core fire resisting enhanced cable.In the event of a break in the network loop the system will continue to function.All outstations are powered from the line including the roaming telephone enclosure and disabled toilet alarms.Optional link to fire detection system prevents hoax disabled refuge calls C2CFPE required. Firefighter roaming telephones and toilet alarms remain active.Speech steered disabled refuge outstations.Full duplex speech firefighter and emergencysteward telephones.Any combination of the following outstations can be installed on a single system Disabled refuge Type B outstations Fire telephones Type A outstations Steward emergency telephones Type A outstations Roaming telephones Disabled toilet alarms.BenefitsStylish versatile and simple to navigate and control.Suitable for small or large systems - fully networkable.Monitored roaming telephone handsets - enables use with confidence.System configuration via SD card front panel or PC connection.Facilitates clear communication during an emergency event.Ideal for retro-fitting old star-wired systems.Quality built robust system.Activityfault log.Outstations including toilet alarms powered directly from the line - no local power needed.Any combination of outstation on one system.

GBP 1539.52
1

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4Care2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall. It is stylish versatile and easy to use and offers an alternative to our well-established loop-wired Omnicare range.Key FeaturesCARE2 is an all-in-one Emergency Voice Communication EVC system.Fully monitored and battery-backed 24 hours quiescent and three hours functional.Fully compliant to BS5839-92011. Assists companies with compliance to BS99992008.Remote units are wired in a radial star configuration using two core fire resisting enhancednon-enhanced cable.Fully networkable. Networked panels are wired in a loop configuration using 2 x two core fire resisting enhanced cable.In the event of a break in the network loop the system will continue to function.All outstations are powered from the line including the roaming telephone enclosure and disabled toilet alarms.Optional link to fire detection system prevents hoax disabled refuge calls C2CFPE required. Firefighter roaming telephones and toilet alarms remain active.Speech steered disabled refuge outstations.Full duplex speech firefighter and emergencysteward telephones.Any combination of the following outstations can be installed on a single system Disabled refuge Type B outstations Fire telephones Type A outstations Steward emergency telephones Type A outstations Roaming telephones Disabled toilet alarms.BenefitsStylish versatile and simple to navigate and control.Suitable for small or large systems - fully networkable.Monitored roaming telephone handsets - enables use with confidence.System configuration via SD card front panel or PC connection.Facilitates clear communication during an emergency event.Ideal for retro-fitting old star-wired systems.Quality built robust system.Activityfault log.Outstations including toilet alarms powered directly from the line - no local power needed.Any combination of outstation on one system.

GBP 1771.76
1

Baldwin Boxall BVOCTSC48 OmnicarePLUS Local Control Panel 48-Way

Baldwin Boxall BVOCTSC48 OmnicarePLUS Local Control Panel 48-Way

Baldwin Boxall BVOCTSC48 OmnicarePLUS Local Control Panel 48-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 7952.52
1

Baldwin Boxall BVOCTSC64 OmnicarePLUS Local Control Panel 64-Way

Baldwin Boxall BVOCTSC64 OmnicarePLUS Local Control Panel 64-Way

Baldwin Boxall BVOCTSC64 OmnicarePLUS Local Control Panel 64-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 8371.64
1

Baldwin Boxall BVOCTSC32 OmnicarePLUS Local Control Panel 32-Way

Baldwin Boxall BVOCTSC32 OmnicarePLUS Local Control Panel 32-Way

Baldwin Boxall BVOCTSC32 OmnicarePLUS Local Control Panel 32-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 7660.39
1

Baldwin Boxall BVOCTSC16 OmnicarePLUS Local Control Panel 16-Way

Baldwin Boxall BVOCTSC16 OmnicarePLUS Local Control Panel 16-Way

Baldwin Boxall BVOCTSC16 OmnicarePLUS Local Control Panel 16-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 6913.78
1

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-Way

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-Way

Baldwin Boxall BVOCTSC08 OmnicarePLUS Local Control Panel 8-WayOmnicarePLUS makes it possible for very large disabled refuge fire telephone EVC systems to be installed.Up until now it has not been possible to install super large EVC systems. However this has all changed you can now have as many as 8064 outstations on a single system We agree that it is extremely unlikely that a system of this size would be required but what it means is that the restrictions have now been liftedOverall site-wide system master control is carried out by the use of a graphic layout on a touch screen PC. The graphic on the screen is multi-layer providing the user with an easy-to-use and instantly recognisable interface for the system.OmnicarePLUS is not limited to a single touch screen control point additional ones can be added to the system enabling placement in alternative control or security rooms. These will be slavesmimic panels unless full control is transferred to the panel due to compromise of the master control point or if required by the users.For local area control i.e. control of the outstations on a single floorareabuilding block specially designed Omnicare panels are employed. Up to 64 outstations can be connected to a local area control panel. Each local area control panel is able to communicate with the outstations connected to that unit.A standard Omnicare system has the ability to connect to a maximum of 127 outstations. The development of OmnicarePLUS has enabled the installation of much larger scale systems. OmnicarePLUS is made up of multiple BS5839-9 compliant local systems which are then connected to form a network. The benefit of OmnicarePLUS is the ability to communicate with any outstation on any part of the network from a single point. This sitewide control is via a graphical touch screensKey FeaturesAbility to connect up to 125 local control points each with 64 outstations - making it possible to connect up to 8000 remotes.Compatible with the entire range of Omnicare outstations.Choice of copper and fibre single or multi-mode networking.Multi-layer graphical touch screen control - see the location of the remote calling.Automatic incoming call queuing with indication of number of waiting calls.Multiple touch screen control locations with optional mimicking of status and faults.Incoming call logging and audio recording via touch screen control locations.All site wiring fully monitored for faults and any faults will be reported and recorded in a time and date stamped log.The network is fault tolerant so that the system will continue to operate in the presence of a single fault.Calls can be accepted locally at Omnicare panels.Optional pin number-based access control at touch screen control locations.Activity reporting including faults detected with date and time stamp.All call announcements can be made via an MCP - paging will be heard at all fire telephones steward telephones and occupied disabled refuge points.A conference call can be initiated from the MCP or an LCP to communicate with the fire and steward telephones connected to a single LCP.System DesignEach OmnicarePLUS project is unique. We have a qualified team that will design build and test the system to suit your specification. If you have a requirement for a particularly large EVC system then please contact our Sales Team who will be happy to discuss your options.

GBP 6586.27
1

Baldwin Boxall Touch Screen Microphone BVRDTSM

Baldwin Boxall Touch Screen Microphone BVRDTSM

Baldwin Boxall Touch Screen Microphone BVRDTSMIntroducing the new EN54 certified touch screen control microphone a multi-function user interface for VIGIL voice alarm systems.The BVRDTSM is an easy to use microphone with a touch sensitive screen that provides full control of the voice alarm system. Special features include a Near Field Communication NFC smart card user access facility.The microphone is a stylish unit which has all the functions that you would expect from a voice alarm system control microphone. It provides the user with unique options such as connecting a third-party music feed directly to the microphone to broadcast to selected areas or zones.The unit has a dual output ability which provides the opportunity to route a broadcast via an alternative rack on the system ideal for sites where separate A and B circuit racks are required. Another feature is the hard-wired bypass input which enables an emergency all call announcement in the unlikely event of a processor failure.With straight-forward multi-page scroll through operation the microphone enables full control of a VIGIL voice alarm system including access allowingZone or all call selection.Live speech for general paging announcements.Emergency paging facility given highest priority on the system automatically overriding all other broadcasts.Select system stored messages general and critical with priority given to the most critical for broadcast to chosen zones.Operators can use the microphone to record non-critical messages and store them for future use.A third-party music audio feed can be connected to the microphone. The output can then be routed by the user to a single or combination of zones.Select and route background music for broadcast to individual or multiple zones.Volume adjustment function provides the ability to change the volume of non-critical broadcasts to selected zones.View detailed activity history and fault logs.Configurable group buttons enable selection of multiple zones by a single touch.Configurable function buttons enable automatic multiple message playback.Key FeaturesStylish easy-to-use control microphone with a capacitive touch bright seven-inch screen.Emergency control mode live emergency broadcasts from the unit will override messages triggered by the fire panel.Near Field Communications NFC for card or pin based operator log-in feature enabling access to a pre-determined level of control.Dual output facility providing the ability to route the broadcast via a different rack on the system for sites where separate AB circuit racks are required.A hard-wired bypass input enables an emergency all call announcement in the unlikely event of a processor failure. There is also an option to fit an emergency bypass all call switch to the microphone.Critical signal path monitoring of the system - all faults being visibly and audibly indicated at the microphone.Compatible with VIGIL2 and VIGIL3 all microphone configuration is performed via the touch screen.

GBP 1654.73
1

Baldwin Boxall Vigil 3 Audio Output Module BV3AOM8

Baldwin Boxall BV3AIM4 Vigil 3 Four Way Audio Input Module

Baldwin Boxall BV3AIM2 Two Way Vigil 3 Audio Input Module