8 results (0,16406 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo 45681-330APO Intelligent Sounder Visual Indicator Base with Isolator

Apollo White Multi-Tone Open-Area Sounder Beacon with Isolator - 55000-294APO

Apollo White Weatherproof Multi-Tone Open-Area Sounder Beacon with Isolator - 55000-299APO

Apollo White Multi-Tone Open-Area Sounder - 55000-279APO

Apollo AlarmSense Base 45681-244APO

Apollo AlarmSense Integrating Optical Smoke Detector with Sounder Base 55000-393APO

Apollo AlarmSense Integrating Optical Smoke Detector with Sounder Base 55000-393APO

Please note This product is obsolete but we do have limited stock available. Please contact us for further information.Apollo AlarmSense Integrating Optical Smoke Detector with Sounder Base 55000-393The AlarmSense Integrating Optical Smoke Detector works using the light scatter principle. The detector also has the ability to monitor and discard transient sources of smoke. AlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires making installation quicker and less expensive. AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings.The range also allows an existing system to be extended or modified if necessary. This flexibility makes AlarmSense an excellent choice for use in HMOs House in Multiple Occupation. As you would expect from Apollo AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products such as beacons to help meet the requirements of the Disability Discrimination Act DDA.Key FeaturesResponds well to slow-burning smouldering firesWell suited for bedrooms and escape routes360C visibility of LEDsReduces false alarmsQuick and simple installationDesigned to operate in environments where transient levels of smoke may be expectedReduces false alarms20 second delayAlarmSense FeaturesFlexibleReliableCost-effectiveCompliant with BS 5839Easy to installEasy to extend

GBP 29.43
1

Apollo Deckhead Mounting Box 45681-217APO

Apollo Deckhead Mounting Box 45681-217APO

Apollo Deckhead Mounting Box 45681-217APOMechanical ConstructionThe Deckhead Mounting Box is used on its own in most cases but there are applications where either an extension sleeve or an adaptor ring is required. The Extension Sleeve is required when fitting heater or deep bases the Adaptor Ring is needed for fitting sounder bases beacon bases or sound beacon bases. Further details are given in the table below. The Extension Sleeve and the Adaptor Ring are sold as an Accessory Kit part no 45681-218.The Deckhead Mounting Box has 6 cable access ports for M20 glands and is secured to the mounting surface via two 5.4mm holes in the webs.Additional InformationFor more information refer to Installation Guide 39214-450 and Datasheets PP2364 PP2040.Safety NoteNOTES ON USE 1. Do not apply any sealing compound or use a gasket of any kind between the detector base and deckhead mounting box 2. Ensure that if a terminal block is fitted it does not contact or foul the detector base 3. Ensure that the mounting surface is flat and Level 4. Seal unused cable access ports with suitable blanking plugs. Sealing compound may be used provided that it does not at any time give off fumes or vapour which could affect any detector fitted to the base 5. The deckhead mounting box orientation should be such that the detector LED is facing the entrance to the protected areaProduct InformationThe Deckhead Mounting Box part no 45681-217 is a device which protects bases sounder bases and sounder beacon bases from the ingress of water or other liquids. It is screwed to the soffit and accepts a variety of Apollo bases.Key FeaturesProtects against water ingressImproved performanceAvailable in polycarbonate or metalPolycarbonate deckhead mounting box 45681-217 also fits Apollo audio visual bases when used with the accessory kit 45681-218Additional Information 3Weight of DeckheadMounting Box Backbox 100gExtension sleeve 23gAdaptor Ring 29g

GBP 12.54
1

Apollo Discovery Carbon Monoxide CO Detector 58000-300APO

Apollo Discovery Carbon Monoxide CO Detector 58000-300APO

Apollo Discovery Carbon Monoxide CO Detector 58000-300APODiscovery CO fire detectors contain a long-life electro-chemical carbon monoxide sensor which is tolerant of low levels of common vapours and household products. The sensing technology is fast accurate and needs only very low power. The detection capabilities are enhanced by a rate-sensitive response. Fast rises in the carbon monoxide level are often associated with hot fires and the detector will respond earlier under these conditions. The analogue reply from the detector is rate limited to remove nuisance alarms resulting from short-term high levels caused by sources such as pipe smokers or gas flame ignition.Brand InformationDiscovery is a range of high-specification analogue addressable fire detectors and alarm devices. Discovery detectors offer effective false alarm management by a combination of EN 54 approved operating modes and sophisticated algorithms. Drift compensation further reduces the likelihood of false alarms caused by a build-up of dust in the sensing chamber. In addition to the familiar smoke and heat detectors the Discovery range features two multisensor detectors. One is an opticalheat multisensor which can be used to protect against many types of fire risk. The other is a carbon monoxideheat multisensor which protects against both smouldering fires and those generating heat.OperationThe Discovery CO detector has five operating modes each having a set combination of sensitivity and response delay which the user can select for any given application.ApplicationCO detectors do not detect smoke particles or heat and are not universal replacements for smoke detectors. Apollo does not endorse the use of CO detectors as the main method of fire detection if the protected area is an escape route there is a requirement to detect overheating of electrical equipment or cables the protected area is exposed to sources of CO such as vehicle exhausts or to hydrogen or to high levels of alcohol vapour as emitted by some cleaning agents there is a requirement to detect fires involving flammable liquids CO fire detectors are particularly suitable for supplementing smoke detection when there is a deep seated smouldering fire risk a risk of fire starting in an enclosed space a likelihood of stratification taking place Carbon monoxide detectors may be used as the primary fire detector in areas where the following conditions exist the main risk is smouldering fires optical smoke detectors are deemed unsuitable see FALSE ALARMS below the fire compartment is not greater than 50m2 Typical applications include hotel bedrooms halls of residence sheltered accommodation and hospital wards.CommunicationDiscovery uses a digital communications protocol which has been developed from the XP95 protocol but differs in that it allows communication in three different modes Normal Read and Write to allow a more extensive exchange of information and commands than previous analogue addressable ranges. In addition Discovery can store data in non-volatile memory. The Normal mode is identical to the XP95 protocol with the exception that the five additional analogue value bits in the XP95 protocol extension have been re-defined so that the fire control panel is able to distinguish between Discovery and XP95 devices. The Read mode is used to check information stored in the non-volatile memory of each detector. It is accessed by using a simple extension to the Normal mode communication method from the fire control panel to the detector. In Write mode the fire control panel is able to write information to the detector by extending the communication method in the same way as in Read mode. During Read or Write modes a detector can signal an alarm by means of the alarm flag and alarm address bits. Discovery detectors are compatible with XP95 and Soteria. It should be noted however that Discovery features will not be available when Discovery is used with XP95 fire control panels. Fire control panels with drift compensation algorithms should disable the algorithms when communicating with Discovery. For fire control panels running CoreProtocol please refer to the fire control panel manufacturers operating instructions.

GBP 62.71
1