7 results (0,13132 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Advanced MxPro5 MXP-544 P-BUS 8-Way Relay Card

Advanced MxPro5 MXP-544F P-BUS 8-Way Relay Card Fitted

Advanced 20-VMMC120-ADV Single Relay Powered Output Module With Built In Isolator

Advanced QuickZone XL 32 Zone Conventional Control Panel - QZXL-32

Advanced QuickZone XL 32 Zone Conventional Control Panel - QZXL-32

Advanced QuickZone XL 32 Zone Conventional Control Panel - QZXL-32The QuickZone XL 32 is a 16 to 32 Zone Conventional Control Panel with integral power supply and space for appropriate standby batteries. The panel extends the QuickZone range with the same high levels of quality and reliability as well as remaining easy to install maintain and simple to use for the end user. Up to 32 fire zone circuits are provided as well as four monitored sounder circuits complete with 500mA resettable fuses.Fire and fault VFCO relays along with fire fault disablement and reset programmable switched negative outputs. Class change and alert inputs are also available.DIL switches within the panel are used to allow Zone Interface setting and also to allow access to level 3. Dependency modes A B and C are available to help reduce false alarms. The panel is very cost effective and even allows for one man walk tests.Key Features16 24 or 32 Zones3 Modes to manage false alarmsOne man walk testKey-switch or code entry for accessThree year warranty as standardSpace for two 18AHr batteriesIntegral 5 Amp switch mode PSUProgrammable relays outputsApproved to EN54-2 4Network up to 8 control panelsFour monitored sounder circuitsClass change alert programmable inputsFire alarm routing outputTest mode with or without soundersIntegral detector removal monitoringSpacious enclosure for easy installation and cablingThree year warranty as standard

GBP 1875.49
1

Advanced QuickZone XL 16 Zone Conventional Control Panel - QZXL-16

Advanced QuickZone XL 16 Zone Conventional Control Panel - QZXL-16

Advanced QuickZone XL 16 Zone Conventional Control Panel - QZXL-16The QuickZone XL 32 is a 16 to 32 Zone Conventional Control Panel with integral power supply and space for appropriate standby batteries. The panel extends the QuickZone range with the same high levels of quality and reliability as well as remaining easy to install maintain and simple to use for the end user. Up to 32 fire zone circuits are provided as well as four monitored sounder circuits complete with 500mA resettable fuses.Fire and fault VFCO relays along with fire fault disablement and reset programmable switched negative outputs. Class change and alert inputs are also available.DIL switches within the panel are used to allow Zone Interface setting and also to allow access to level 3. Dependency modes A B and C are available to help reduce false alarms. The panel is very cost effective and even allows for one man walk tests.Key Features16 24 or 32 Zones3 Modes to manage false alarmsOne man walk testKey-switch or code entry for accessThree year warranty as standardSpace for two 18AHr batteriesIntegral 5 Amp switch mode PSUProgrammable relays outputsApproved to EN54-2 4Network up to 8 control panelsFour monitored sounder circuitsClass change alert programmable inputsFire alarm routing outputTest mode with or without soundersIntegral detector removal monitoringSpacious enclosure for easy installation and cablingThree year warranty as standard

GBP 1118.28
1

Advanced QuickZone XL 24 Zone Conventional Control Panel - QZXL-24

Advanced QuickZone XL 24 Zone Conventional Control Panel - QZXL-24

Advanced QuickZone XL 24 Zone Conventional Control Panel - QZXL-24The QuickZone XL 32 is a 16 to 32 Zone Conventional Control Panel with integral power supply and space for appropriate standby batteries. The panel extends the QuickZone range with the same high levels of quality and reliability as well as remaining easy to install maintain and simple to use for the end user. Up to 32 fire zone circuits are provided as well as four monitored sounder circuits complete with 500mA resettable fuses.Fire and fault VFCO relays along with fire fault disablement and reset programmable switched negative outputs. Class change and alert inputs are also available.DIL switches within the panel are used to allow Zone Interface setting and also to allow access to level 3. Dependency modes A B and C are available to help reduce false alarms. The panel is very cost effective and even allows for one manwalk tests.Key Features16 24 or 32 Zones3 Modes to manage false alarmsOne man walk testKey-switch or code entry for accessThree year warranty as standardSpace for two 18AHr batteriesIntegral 5 Amp switch mode PSUProgrammable relays outputsApproved to EN54-2 4Network up to 8 control panelsFour monitored sounder circuitsClass change alert programmable inputsFire alarm routing outputTest mode with or without soundersIntegral detector removal monitoringSpacious enclosure for easy installation and cablingThree year warranty as standard

GBP 1512.88
1

Advanced QZXL-HSZEC QuickZone XL 4 Zone Expander Card High Spec

Advanced QZXL-HSZEC QuickZone XL 4 Zone Expander Card High Spec

Advanced QZXL-HSZEC QuickZone XL 4 Zone Expander Card High SpecQuickZone XL is up to 12 zone Conventional Twin Wire sav-wire control panel with integral power supply space for standby batteries.The panel continues the attributes of quality and reliability that is easy to install maintain and is simple to operate for the end user. Up to 12 fire zone circuits are provided plus two monitored sounder circuits.Fire and fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included. The fire zone outputs can be set as Twin Wire by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode.Dependency modes A B C available. In Level 1 the panel will indicate if there are any faults Supply Fire System General repeater.As well as this the panel is capable of indicating zones in Fire Fault and disablements and delay status. Auxiliary Output and Sounder status will be shown including if the panel is in test mode. Controls enabled in Level 2 include Resound Silence and Reset.Disable and Test modes can also be established at this level as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3 it is possible to select sounder resound options for zones EN54 requirement select Type A dependency per view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set and the event log viewed. Panel wide settings including access codes and delays. Two Additional monitored sounder outputs programmable switched negative outputs and one programmable relay available with high specification expansion card.Key FeaturesIntegral detector removal monitoringTwo monitored sounder circuits fitted as standardSpace for up to 2 x 7.0Ah batteriesKey-switch or code entry for activation of controlsCan support up to 8 fully functional repeater panels2 Additional sounder circuits with high spec expansion cardModular expansion zone cards availableAlarm load of 2.4A shared across all sounder outputsTest Mode with or without soundersProgrammable relays and outputsClass Change Alert programmable inputsIntegral 3 Amp switch mode PSUThree-year warranty as standardFully approved to EN54-2 44 to 12 Zones4 x conventional or Twin Wire zone circuits2 x switched ve outputs1 x Aux relay output2 x monitored sounder circuits

GBP 220.18
1