9 results (0,12810 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton ZP886R ZP7 Series Intelligent Addressable Manual Call Point

Ziton ZP886R ZP7 Series Intelligent Addressable Manual Call Point

Ziton ZP886R ZP7 Series Intelligent Addressable Manual Call PointThe Ziton ZP886R is a red single action indoor Manual CallPoint MCP. It comes with resettable element test connector and test key.Multiple optional accessories are available to facilitate most indoorinstallation requirements.It is a standard profile indoor MCP suitable for surfaceand recess mount installations using standard or legacy European electricalboxes. With its designer dual tricolour LEDs it offers 180 clear localindication of its operational status even from a side view in a passageinstallation. Front access test key facility allows unhindered accessregardless of the installation location. The key doubles as a test anddisassembly tool allowing removal of the MCP front cover without the need foradditional tools. Deploy seamlessly into existing legacy systems without CIEconfiguration changes.Key FeaturesRed single actionReliable single action manual call point for surface andflush mountingDual tri-colour status indicators offers 180 alarmvisibilityTamper resistant design with resettable or frangible elementUnobtrusive front facing test facilityStandard mounting options facilitates easy retrofitting toexisting installationsMatching back box with rear top and bottom cable entryScreen connection terminal for electrically noisyinstallationsPluggable connector with link through facility for ease ofinstallation and pre-commissioning testingAn alarm flag on the face of the manual call point allowsalarm indication even without alarm LEDsFast no-tools-required maintenance using the test keyUp to 127 devices per loop

GBP 46.31
1

Ziton ZP888R ZP7 Series Intelligent Addressable Manual Call Point Weatherproof

Ziton ZP888R ZP7 Series Intelligent Addressable Manual Call Point Weatherproof

Ziton ZP888R ZP7 Series Intelligent Addressable Manual Call Point WeatherproofThe ZP880 Series is an intelligent range of addressable manual call points. The ZP888R is a red single action weatherproof MCP. It is delivered complete with resettable element test connector and test key. Multiple optional accessories are available to facilitate most outdoor installation requirements.This weatherproof single action MCP is a standard profile outdoor MCP suitable for surface mount installations using the back box supplied with the product. With its designer dual tricolour LEDs it offers 180 clear local indication of its operational status even from a side view. The clean face of the MCP is further enhanced by a front access test key facility that allows access to the activation element that can be either frangible or resettable.Key FeaturesReliable single action manual call point for surface mountingA dual tri-colour status indicator offers 180 alarm visibilityTamper resistant design with resettable or frangible elementUnobtrusive front facing test facilityOutdoor rated waterproof enclosureBack box with top and bottom cable entryScreen connection terminal for electrically noisy installationsPluggable connector with link through facility for ease of installation and pre-commissioning testingAlarm flag on the face of the MCP allows maintenance indication even without alarm indicatorsFast no-tools-required maintenance using the test keyUp to 127 devices per loop

GBP 167.68
1

Ziton ZP886R-KITF Intelligent Addressable Manual Call Point - Red cw Back Box amp Flip Cover

Ziton ZP886R-KITF Intelligent Addressable Manual Call Point - Red cw Back Box amp Flip Cover

Ziton ZP886R-KITF Intelligent Addressable Manual Call Point - Red cw Back Box Flip CoverThe Ziton ZP886R is a red single action indoor Manual Call Point MCP. It comes with resettable element test connector and test key. Multiple optional accessories are available to facilitate most indoor installation requirements.It is a standard profile indoor MCP suitable for surface and recess mount installations using standard or legacy European electrical boxes. With its designer dual tricolour LEDs it offers 180 clear local indication of its operational status even from a side view in a passage installation. Front access test key facility allows unhindered access regardless of the installation location. The key doubles as a test and disassembly tool allowing removal of the MCP front cover without the need for additional tools. Deploy seamlessly into existing legacy systems without CIE configuration changes.Key FeaturesRed single actionReliable single action manual call point for surface and flush mountingDual tri-colour status indicators offers 180 alarm visibilityTamper resistant design with resettable or frangible elementUnobtrusive front facing test facilityStandard mounting options facilitates easy retrofitting to existing installationsMatching back box with rear top and bottom cable entryScreen connection terminal for electrically noisy installationsPluggable connector with link through facility for ease of installation and pre-commissioning testingAn alarm flag on the face of the manual call point allows alarm indication even without alarm LEDsFast no-tools-required maintenance using the test keyUp to 127 devices per loopComes with back box and flip cover

GBP 50.39
1

Ziton ZP886W ZP7 Addressable Manual Call Point White

Ziton ZP886W ZP7 Addressable Manual Call Point White

Ziton ZP886W ZP7 Addressable Manual Call Point WhiteThe Ziton ZP886W is a white single action addressable indoor manual call point. It is delivered complete with resettable element test connector and test key. Multiple optional accessories are available to facilitate most indoor installation requirements.This single action MCP is a standard profile indoor MCP suitable for surface and recess mount installations using standard or legacy European electrical boxes. With its designer dual tricolour LEDs it offers 180 clear local indication of its operational status even from a side view in a passage installation. The clean face of the MCP is further enhanced by a front access and test key facility.CompatibilityThe ZP880 range may be used on compatible Ziton fire systems. They can be deployed seamlessly into existing legacy systems without CIE configuration changes.Installation and maintenance friendlyThe front-facing access for an aesthetically matching test key allows unhindered access regardless of the installation location. The MCP key doubles as a test and disassembly tool allowing removal of the MCP front cover without the need for additional tools.Key FeaturesReliable single action manual call point for surface mountingA dual tri-colour status indicator offers 180 alarm visibilityTamper resistant design with resettable or frangible elementStandard mounting options facilitates easy retrofitting to existing installationsUnobtrusive front facing test facilityMatching back box with rear top and bottom cable entryScreen connection terminal for electrically noisy installationsPluggable connector with link through facility for ease of installation and pre-commissioning testingAlarm flag on the face of the MCP allows alarm indication even without alarm LEDsFast no-tools-required maintenance using the test keyUp to 127 devices per loop

GBP 74.71
1

Ziton ZP886R-TSKIT ZP7 Series Intelligent Addressable Manual Call Point cw Skirt

Ziton ZP886R-RMKIT ZP7 Series Intelligent Addressable Manual Call Point - Recess Mount

Ziton FD310H - Additional Detector Pair 5 - 120m for FD310

Ziton FD310H - Additional Detector Pair 5 - 120m for FD310

ZitonFD310H - Additional Detector Pair 5 - 120m for FD310The FD310 End to End infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronic and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.OperationThe system comprises a modern looking Transmitter head which emits a narrow beam of infra-red light to an associated Receiver head with a compact Low Level Controller. Once smoke crosses through and thus obscures the IR beam path the signal strength at the Receiver drops below a preset level which in turn results in an alarm condition. Both the detector heads Transmitter and Receiver have integrated alignment thumbwheels for ease of alignment. Using these thumbwheels provides a smooth and repeatable alignment process. The detector heads have up to 10 degrees of adjustment in both planes. For further adjustment a bespoke Adjustment Bracket is available which offers up to 180 degrees movement in both planes as well as a full 360-degree rotation.The FD310 has been designed so that it can be installed by one operator with its laser assisted alignment method combined with easy to use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the Controller or at the Receiver head.The low level Controller incorporates a LCD display which offers a full icon-based easy-to-use interface unit. This Controller enables ease of commissioning testing and maintenance of the beam detection system. During commissioning the detector sensitivity and fire thresholds can be selected along with the user variable time to fire and time to fault settings.Key FeaturesSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from Controller

GBP 789.20
1

Ziton FD310 End-to-End Beam Detector 5 to 120m

Ziton FD310 End-to-End Beam Detector 5 to 120m

Ziton FD310 End-to-End Beam Detector 5 to 120mOptical beam smoke detector consists of separate transmitter and receiver heads and a low level controller.The FD310 End to End infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronic and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.The system comprises a modern looking Transmitter head which emits a narrow beam of infra-red light to an associated Receiver head with a compact Low Level Controller. Once smoke crosses through and thus obscures the IR beam path the signal strength at the Receiver drops below a pre-set level which in turn results in an alarm condition. Both the detector heads Transmitter and Receiver have integrated alignment thumbwheels for ease of alignment. Using these thumbwheels provides a smooth and repeatable alignment process. The detector heads have up to 10 degrees of adjustment in both planes. For further adjustment a bespoke Adjustment Bracket is available which offers up to 180 degrees movement in both planes as well as a full 360-degree rotation.The FD310 has been designed so that it can be installed by one operator with its laser assisted alignment method combined with easy to use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the Controller or at the Receiver head.The low level Controller incorporates a LCD display which offers a full icon-based easy-to-use interface unit. This Controller enables ease of commissioning testing and maintenance of the beam detection system. During commissioning the detector sensitivity and fire thresholds can be selected along with the user variable time to fire and time to fault settings.Range 5 to 120m integral laser alignment controller can support 2 pairs of transmitter and receivers additional pairs are available FD310H.Key FeaturesSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from ControllerSupply voltage 12-36VDCCurrent Controller 14mA per transmitter head 8mAFire and Fault relays per detector head - rated 2A 30VDCDetector head dimensions per transmitter and receiver unit mm 74w x 74h x 161dController dimensions mm 203w x 124h x 73d

GBP 947.02
1